beautypg.com

Delta Electronics Elevator Drive VFD-VL User Manual

Page 190

background image

Chapter 6 Fault Code Information and Maintenance|

Revision Nov. 2008, VLE1, SW V1.03 6-13

„

DC capacity of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any leak of liquid,
color change, crack or
deformation

Visual inspection

{

If the safety valve is not
removed? If valve is inflated?

Visual inspection

{

Measure static capacity when
required

{

„

Resistor of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any peculiar smell or
insulator cracks due to overheat

Visual inspection, smell

{

If there is any disconnection

Visual inspection

{

If connection is damaged?

Measure with multimeter with standard
specification

{

„

Transformer and reactor of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any abnormal vibration
or peculiar smell

Visual, aural inspection and smell

{