Chapter 4 Parameters|

4-20

Revision Nov. 2008, VLE1, SW V1.03

4.2 Description of Parameter Settings

Group 0 User Parameters : This parameter can be set during operation.

00-00

Identity Code of the AC Motor Drive

Control

mode

VF VFPG SVC

FOCPG TQCPG FOCPM

Factory setting: ##

Settings Read

Only

00-01

Rated Current Display of the AC Motor Drive

Control

mode

VF VFPG SVC

FOCPG TQCPG FOCPM

Factory setting: ##

Settings

Read

Only

Pr. 00-00 displays the identity code of the AC motor drive. The capacity, rated current, rated

voltage and the max. carrier frequency relate to the identity code. Users can use the following

table to check how the rated current, rated voltage and max. carrier frequency of the AC motor

drive correspond to the identity code.

Pr.00-01 displays the rated current of the AC motor drive. By reading this parameter the user

can check if the AC motor drive is correct.

230V Series

kW

5.5 7.5 11 15 18.5 22 30 37

HP

7.5 10 15 20 25 30 40 50

Pr.00-00

12 14 16 18 20 22 24 26

Rated Output Current for General

Purposes (A)

21.9

27.1 41 53 70 79 120 146

Rated Output Current for Elevators (A)

25

31

47

60

80

90

150

183

Max. Carrier Frequency

15kHz

9kHz

460V Series

kW

5.5

7.5

11 15 18.5 22 30 37 45 55 75

HP

7.5

10 15 20 25 30 40 50 60 75 100

Pr.00-00

13 15 17 19 21 23 25 27 29 31 33

Rated Output Current for General

Purposes (A)

12.3

15.8

21 27 34 41 60 73 91 110

150

Rated

Output

Current

for

Elevators

(A)

14 18 24 31 39 47 75 91 113

138

188

Max. Carrier Frequency

15kHz

9kHz

6kHz