3.3 Auto-tuning Operations

3.3.1 Flow Chart

IM

PM

St ep 1 Basic parameter set ting s

Source of the Master
Frequency C omm and
Pr. 00-14

Sett ing all parameters
to factory setting
Pr. 00-02

Source of the
Operation C omm and
Pr.00-15

MI/M O terminals Settings
Pr.02-01~02-08
Pr.02-13~02-22

St ep 2 Mot or tu nin g

Motor ty pe
[PM/IM ]

Control M ode Select ion
Pr.00-09

Sett ing t he relat ed
informat ion of IM motor
Pr. 01-00~01-02

Pr.05-01~05-04

Sett ing t he relat ed
informat ion of PM motor
Pr.01-00~01-02

Pr.08-01~08-04

IM M otor Aut o-tuning
Pr.05-00

PM Motor Auto-t uning
Pr.08-00

St ep 3 En coder settin gs

Selection of speed
feedbac k card
EMVL-PGABL

EMVL-PGABO
EMVL-PGH01
EMVL-PGS01

Detection of the HOME
position of Encoder
1. us ing digital k eypad

2. us ing external terminals

Sett ing Encoder information
Pr.10-00~10-02

Encoder selection
Pr.10-00

St ep 4 Mult i- step speed sett ings

Sett ing s peed, accel/decel. t ime and S curve
Pr.04-00~04-15
Pr.01-12~01-19

Pr.01-24~01-30

St ep 5 Trial run

Trial run

Smooth test
Pr.11-00 bit0=1
Pr.11-05~11-08

1. tuning as start-up
2. tuning as stop

St ep 6 Elevat or tu nin g