Delta Electronics Elevator Drive VFD-VL User Manual
Page 156

Chapter 4 Parameters|
Revision Nov. 2008, VLE1, SW V1.03 4-101
10-12
ASR (Auto Speed Regulation) Control (I) of Zero Speed
Unit: 0.001
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.100
Settings
0.000 to 10.000 sec
10-13
ASR (Auto Speed Regulation) control (P) 1
Unit: 0.1
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 100.0
Settings
0.0 to 500.0%
10-14
ASR (Auto Speed Regulation) control (I) 1
Unit: 0.001
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.100
Settings
0.000 to 10.000 sec
10-15
ASR (Auto Speed Regulation) control (P) 2
Unit: 0.1
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 100.0
Settings
0.0
to
500.0%
10-16
ASR (Auto Speed Regulation) control (I) 2
Unit: 0.001
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.100
Settings
0.000 to 10.000 sec
10-17
ASR 1/ASR2 Switch Frequency
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 7.00
Settings
0.00 o 120.00Hz
0.00:
disable
ASR P determines Proportional control and associated gain (P). ASR I determines integral
control and associated gain (I).
When integral time is set to 0, it is disabled. Pr.10-17 defines the switch frequency for the
ASR1 (Pr.10-13, Pr.10-14) and ASR2 (Pr.10-15, Pr.10-16).
10-17
10-13
10-14
10-15
10-16
Hz
PI
10-11
10-12
0Hz
10-20
10-21