beautypg.com

Delta Electronics Elevator Drive VFD-VL User Manual

Page 156

background image

Chapter 4 Parameters|

Revision Nov. 2008, VLE1, SW V1.03 4-101

10-12

ASR (Auto Speed Regulation) Control (I) of Zero Speed

Unit: 0.001

Control

mode

VF

VFPG

SVC

FOCPG FOCPM

Factory Setting: 0.100

Settings

0.000 to 10.000 sec

10-13

ASR (Auto Speed Regulation) control (P) 1

Unit: 0.1

Control

mode

VF

VFPG

SVC

FOCPG FOCPM

Factory Setting: 100.0

Settings

0.0 to 500.0%

10-14

ASR (Auto Speed Regulation) control (I) 1

Unit: 0.001

Control

mode

VF

VFPG

SVC

FOCPG FOCPM

Factory Setting: 0.100

Settings

0.000 to 10.000 sec

10-15

ASR (Auto Speed Regulation) control (P) 2

Unit: 0.1

Control

mode

VF

VFPG

SVC

FOCPG FOCPM

Factory Setting: 100.0

Settings

0.0

to

500.0%

10-16

ASR (Auto Speed Regulation) control (I) 2

Unit: 0.001

Control

mode

VF

VFPG

SVC

FOCPG FOCPM

Factory Setting: 0.100

Settings

0.000 to 10.000 sec

10-17

ASR 1/ASR2 Switch Frequency

Unit: 0.01

Control

mode

VF

VFPG

SVC

FOCPG FOCPM

Factory Setting: 7.00

Settings

0.00 o 120.00Hz

0.00:

disable

ASR P determines Proportional control and associated gain (P). ASR I determines integral

control and associated gain (I).

When integral time is set to 0, it is disabled. Pr.10-17 defines the switch frequency for the

ASR1 (Pr.10-13, Pr.10-14) and ASR2 (Pr.10-15, Pr.10-16).

10-17

10-13
10-14

10-15
10-16

Hz

PI

10-11

10-12

0Hz

10-20

10-21