Chapter 4 Parameters|

4-74

Revision Nov. 2008, VLE1, SW V1.03

06-26

PTC (Positive Temperature Coefficient) Detection Selection

Control

mode

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Factory setting: 0

Settings

0

Warn and keep operating

1

Warn and ramp to stop

It is used to set the treatment after detecting PTC.

06-27

PTC Level

Unit: 0.1

Control

mode

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Factory setting: 50.0

Settings

0.0

to

100.0%

It is used to set the PTC level, and the corresponding value for 100% is max. analog input

value.

06-28

Filter Time for PTC Detection

Unit: 0.01

Control

mode

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Factory setting: 0.20

Settings

0.00 to 10.00 sec

06-29

EPS Voltage

Unit: 0.1

Control

mode

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Settings

48.0~375.0Vdc

Factory setting: 48.0

96.0~750.0Vdc

Factory setting: 96.0

It is used with the setting 43 (EPS function) of Pr.02-01~02-08 (Multi-Function Input

Command).