beautypg.com

Class attributes instance attributes – Rockwell Automation 2100-GK61 DeviceNet to SCANport User Manual

Page 175

background image

Publication 2100-UM001B-EN-P – January 2001

DeviceNet Objects

C-21

Class Code 0x98 — SCANport
Pass-Through Warning Object

The SCANport Pass-Through Warning Object provides information
on the product’s warning queue.

Class Attributes

Instance Attributes

Attribute

ID

Access

Rule

Name

Data

Type

Description

0

Set

Write
Warning
Command

BYTE

Write Warning
Command.
1 = Clear Warnings
2 = Clear Warning
Queue
3 = Reset Product

1

Set

Read
Number of
Warning
Queue
Entries

BYTE

Attribute

ID

Access

Rule

Name

Data

Type

Description

0

Get

Read
Warning
Queue
Entry Full/
All Info

STRUCT

of

Warning
Text

ARRAY

of BYTE

16 character string (no
length information, no
terminating null).

Warning
Code

WORD

Fault Code.

Warning
Time
Stamp
(Time
Stamps not
available in
all
products)

STRUCT

BYTE

1/100 Second (0 – 99).

BYTE

Second (0 – 59).

BYTE

Minute (0 – 59).

BYTE

Hour (0 – 23).

BYTE

Day of Week (0 – 6).

BYTE

Date (1 – 31).

BYTE

Month (1 – 12).

BYTE

Year (0 – 99

).

Sunday is a value of zero.

Year is an offset from 1990.