Fan# - The fan number. The system has five cooling fans. Fans 1 to 4
are managed by the fan control feature. Fan 5 operates at its highest
possible speed at all times.
RPM - The current speed of the fan in revolutions per minute (RPM).
The highest speed is approximately 11,000 RPM for fans 1 to 4 and
6,500 RPM for fan 5. RPM is displayed in increments of 100.
% - The speed of the fan as a percentage of its highest possible
operating speed.
Status - A status message.
Temperature - The ambient air temperature measured where the air
enters the cooling vents of the switch.
PoE Current Load - The total current load of the PoE devices.
The minimum operating speed for a fan is 4,000 RPM. A fan falling below
or unable to attain that speed is considered as failed.
If a fan in a switch fails when the fan control feature is activated, the switch
proportionally increases the speed of the remaining operational fans to
compensate for the loss of the failed fan.