SET LOG OUTPUT

Syntax

set log output=

output-id

[destination=syslog]

server=

ipaddress

[facility=default|local1|local2|local3|local4|local5|local6
|local7] [syslogformat=extended|normal] [module=all|

module

]

[severity=all|

severity-list

]

Parameters

output

Specifies an ID number of the output definition to be
modified. The range is 2 to 20.

destination

Specifies the destination for the log messages. The
only option currently supported is:

syslog

Forwards log messages in syslog format
to a syslog server.

server

Specifies a new IP address for the syslog server.

facility

Specifies a facility level to be added to the events.

default

Adds a facility level based on the

functional groupings defined in the RFC
3164 standard. The codes applicable to
the AT-S62 management software and
its modules are shown in Table 6 on
page 236.
This is the default setting.

local1 to local7

Adds a set facility code of 17 (LOCAL1)
to 23 (LOCAL7) to all event messages.
For a list of the levels and their
corresponding codes, refer to Table 7 on
page 236.

syslogformat

Specifies the format of the generated messages. The

possible options are:

extended

Messages include the date, time, and
system name. This is the default.

normal

Messages do not include the date, time,
and system name.