Allied Telesis AT-S62 User Manual
Page 152

Chapter 7: Port Parameter Commands
152
Section I: Basic Operations
Note
The information for an SFP or GBIC module includes additional
nonadjustable operating specifications of the module.
An example of the information displayed by this command is shown in
Figure 13 on page 152.
Figure 13. SHOW SWITCH PORT Command
Examples
The following command displays the operating settings for all ports:
show switch port
The following command displays the operating settings for port 14:
show switch port=14
Port #11 Information:
Port Description ..................... Port_11
Port Type ............................ 10/100Base-T
Status ............................... Enabled
Link State ........................... Down
Configured Speed/Duplex .............. Auto
Configured MDI Crossover ............. N/A
Actual Speed/Duplex .................. -
Actual MDI Crossover ................. -
Flow Control Status .................. Disabled
Flow Control Threshold ............... 57344 cells
Backpressure Status .................. Disabled
Backpressure Threshold ............... 57344 cells
HOL Blocking Prevention Threshold .... 61440 cells
Broadcast Filter ..................... Disabled
Broadcast Rate Limiting Status ....... Disabled
Multicast Rate Limiting Status ....... Disabled
Unknown Unicast Rate Limiting Status . Disabled
Rate ................................. 262143 packet/second
PVID ................................. 1
Port Priority (0-7) 0=Low 7=High...... 0
Override Priority .................... No
Mirroring State....................... Disabled