beautypg.com

Table 9. event log severity levels – Allied Telesis AT-S62 User Manual

Page 253

background image

AT-S62 Management Software Command Line Interface User’s Guide

Section II: Advanced Operations

253

An example of the event log is shown in Figure 23. The example uses
the full display mode.

Figure 23. Event Log Example

The columns in the log are described below:

ˆ

S (Severity) - The event’s severity. Refer to Table 9 on page 253.

ˆ

Date/Time - The date and time the event occurred.

ˆ

Event - The module within the AT-S62 software that generated the
event followed by a brief description of the event. For a list of the
AT-S62 modules, see Table 8 on page 251.

ˆ

Event ID - A unique number that identifies the event. (Displayed only in
the full display mode.)

ˆ

Filename and Line Number - The subsection of the AT-S62 module
and the line number that generated the event. (Displayed only in the
full display mode.)

Table 9. Event Log Severity Levels

Value

Severity Level

Description

E

Error

Switch operation is severely impaired.

W

Warning

An issue may require manager attention.

I

Informational

Useful information that can be ignored
during normal operation.

D

Debug

Messages intended for technical support
and software development.

S Date

Time

EventID

Source File:Line Number

Event

------------------------------------------------------------------
I 2/01/04

09:11:02

073001

garpmain.c:259

garp: GARP initialized

I 2/01/04

09:55:15

083001

portconfig.c:961

pcfg: PortConfig initialized

I 2/01/04

10:22:11

063001

vlanapp.c:444

vlan: VLAN initialization succeeded

I 2/01/04

12:24:12

093001

mirrorapp.c:158

pmirr: Mirror initialization succeeded

I 2/01/04

12:47:08

043016

macapp.c:1431

mac: Delete Dynamic MAC by Port[2] succeeded