SET SWITCH PORT RATELIMITING

Syntax

set switch port=

ports

|all [rate=

value

]

[bcastratelimiting=yes|no|on|off|true|false|enabled|
disabled]
[mcastratelimiting=yes|no|on|off|true|false|enabled|
disabled]
[unkucastratelimiting=yes|no|on|off|true|false|enabled|
disabled]

Parameters

port

Specifies all ports on the switch. This feature cannot
be configured on a per-port basis. You must specify
ALL.

rate

Specifies the number of ingress packets the switch

ports accept each second. This setting applies all
packet types that have their rate limit enabled. The
range is 0 to 262,143.

bcastratelimiting

Enables or disables rate limiting for ingress

broadcast packets. Settings for this parameter are:

yes, on, true, enabled

Activates broadcast

packet rate limit on the
port. The values are
equivalent.

no, off, false, disabled Deactivates

broadcast

packet rate limit on the
port. The values are
equivalent.

mcastratelimiting

Enables or disables rate limiting for ingress

multicast packets. Settings for this parameter are:

yes, on, true, enabled

Activates multicast

packet rate limit on the
port. The values are
equivalent.

no, off, false, disabled

Deactivates multicast
packet rate limit on the
port. The values are
equivalent.

unkucastratelimiting Enables or disables rate limiting for unknown

ingress unicast packets. An unknown unicast packet
is a packet whose destination MAC address has not
been stored in the switch’s MAC address table.
Settings for this parameter are: