Set switch port ratelimiting – Allied Telesis AT-S62 User Manual
Page 141

AT-S62 Management Software Command Line Interface User’s Guide
Section I: Basic Operations
141
SET SWITCH PORT RATELIMITING
Syntax
set switch port=
ports
|all [rate=
value
]
[bcastratelimiting=yes|no|on|off|true|false|enabled|
disabled]
[mcastratelimiting=yes|no|on|off|true|false|enabled|
disabled]
[unkucastratelimiting=yes|no|on|off|true|false|enabled|
disabled]
Parameters
port
Specifies all ports on the switch. This feature cannot
be configured on a per-port basis. You must specify
ALL.
rate
Specifies the number of ingress packets the switch
ports accept each second. This setting applies all
packet types that have their rate limit enabled. The
range is 0 to 262,143.
bcastratelimiting
Enables or disables rate limiting for ingress
broadcast packets. Settings for this parameter are:
yes, on, true, enabled
Activates broadcast
packet rate limit on the
port. The values are
equivalent.
no, off, false, disabled Deactivates
broadcast
packet rate limit on the
port. The values are
equivalent.
mcastratelimiting
Enables or disables rate limiting for ingress
multicast packets. Settings for this parameter are:
yes, on, true, enabled
Activates multicast
packet rate limit on the
port. The values are
equivalent.
no, off, false, disabled
Deactivates multicast
packet rate limit on the
port. The values are
equivalent.
unkucastratelimiting Enables or disables rate limiting for unknown
ingress unicast packets. An unknown unicast packet
is a packet whose destination MAC address has not
been stored in the switch’s MAC address table.
Settings for this parameter are: