beautypg.com

Set switch port – Allied Telesis AT-S62 User Manual

Page 136

background image

Chapter 7: Port Parameter Commands

136

Section I: Basic Operations

SET SWITCH PORT

Syntax

set switch port=

port

[description=”

description

”]

[status=enabled|disabled]
[speed=autonegotiate|10mhalf|10mfull|100mhalf|100mfull|
1000mfull]
[mdimode=mdi|mdix|auto]
[flowcontrol=disable|enable|auto]
[fctrllimit=

value

]

[backpressure=yes|no|on|off|true|false|enabled|disabled]
[bplimit=

value

]

[bcastfiltering=yes|no|on|off|true|false|enabled|disabled]
[holbplimit=

value

]

[renegotiation=auto]
[unkmcastfiltering=yes|no|on|off|true|false|enabled|
disabled]
[softreset]

Parameters

port

Specifies the port to configure. You can specify
more than one port at a time, but the ports must
be of the same medium type. For example, you
cannot configure twisted pair and fiber optic
ports with the same command. You can specify
the ports individually (for example, 5,7,22), as a
range (for example, 18-23), or both (for
example, 1,5,14-22).

description

A description for the port, from 1 to 15
alphanumeric characters. Spaces are allowed,
but special characters should be avoided. If the
description contains a space, enclose it in
double quotes. Otherwise, the quotes are
optional.

status

Specifies the operating status of the port. The

options are:

enabled The port forwards network traffic.

This is the default setting.

disabled The port does not forward network

traffic.

speed

Sets the speed and duplex mode of the port.

The options are: