AlliedView™-EMS 3.11 Device Management Guide

Page 62 of 402

Note

- Enabling/Disabling the Port STP Configuration parameter for one port

enables/disables STP for all ports.

Note

- Attempting to modify the Port Speed and Mode parameter from 'auto sense'

to '1Gbps half-duplex' or '1Gbps full-duplex' will result in the following:

An error message: "The error occurred with 'Set' operation. Error: gen
Error"

Port Speed and Mode parameter value changing to '100Mbps half-duplex'

Note

- The current firmware version does not allow the Port Bridge ID parameter

to be configured. Attempting to configure this parameter will result in the error

message: "The error occurred with 'Set' operation. Error: bad value."

Note

- When a port is set to 'auto sense' and is connected to a half duplex port on

another device, its corresponding Duplex LED on the device image turns green

instead of orange.

Note

- The current firmware version does not allow the Port Back Pressure

parameter to be configured. Attempting to configure this parameter will result in the
error message: "The error occurred with 'Set' operation. Error: time out occurred."

Note

- The Port Transmit Pacing Configuration parameter is not applicable to the

AT-8124XL (V2).

Note

- The current firmware version does not allow the Port VLAN Tag Priority and

the Port QoS Priority parameters to be configured. Attempting to configure these

parameters will result in the error message: "The error occurred with 'Set'
operation. Error: bad value."

Note

- Valid MIB Set values for the Port State parameter are 'enabled' and 'disabled'.

Attempting to set this parameter to any other value will result in the error message:
"The error occurred with 'Set' operation. Error: bad value.".

Spanning Tree Info

Displays the port's spanning tree parameters.


Enable

Enables the port.


Disable

Disables the port.


Port Mirroring

Displays port mirroring parameters and allows configuration of port mirroring state,
source, and destination.