Allied Telesis AlliedView-EMS 3.11 DEVICE MANAGEMENT User Manual
Page 209

AlliedView™-EMS 3.11 Device Management Guide
Page 209 of 402
Ping Status
Displays the status of the Ping polling.
Note
- The current firmware version only allows the Ping Status parameter to
be configured if Protocol parameter under Ping Parameters is set to OSI.
Ping Parameters
Displays basic information of the Ping module.
Note
- Valid MIB Set values for the Timeout parameter should range from 1
to 60. However, the current firmware version allows the user to enter
values in the range [-9223372036854775808 to -1, 1 to
9223372036854775807] inclusive. But attempting to enter values greater
than 65535 will cause the new value to be converted to its equivalent wrap-
around value; i.e., 65536 will become 0, 65537 will become 1, and so on.
Note
- Valid MIB Set values for the Time Interval parameter should range
from 0 to 604800. However, the current firmware version allows the user to
enter values in the range [-9223372036854775808 to
9223372036854775807] inclusive. But attempting to enter values greater
than 999999999 will cause the new value to be converted to its equivalent
wrap-around value; i.e., 9999999990 will become 1410065398, 9999999991
will become 1410065399, and so on.
Note
- Valid MIB Set values for the Number of Packets parameter should
range from 1 to 4294967295. However, the current firmware version does
not allow Device Manager to display the correct value greater than
2147483647. Attempting to enter values greater than 2147483647 will cause
the new value to be converted to its equivalent wrap-around value; i.e.
2147483648 will become -2147483648, 2147483649 will become -
2147483647, and so on.
Note
- The current firmware version only allows the Address parameter to
be configured if the Protocol parameter is set to OSI.
Note
- Valid MIB Set values for the Data Pattern parameter should range
from 1 to 4294967295. However, the current firmware version does not
allow Device Manager to display the correct value greater than 2147483647.
Attempting to enter values greater than 2147483647 will cause the new
value to be converted to the following values:
• 4286578688 - 4294934527: 8388608 - 16744447
• 4294934528 - 4294967167: 32768 - 65407
• 4294967168 - 4294967295: 128 - 255
Note
- Device Manager does not handle objects of type OCTET STRING
correctly. As a result, the Address parameter will not be configurable and
will display a sequence of bytes in hexadecimal format instead of the actual
destination of ping packets.