Device Manager LEDs for AT-MCF12 Family

LED

State

Description

Gray

The backup power supply is not installed or it is installed but

not powered on.

NORM Green

Gray

The unit is not performing a link test.

The unit is performing a link test.

TEST Green

Gray

The unit is performing a link test.

The unit is not performing a link test.

Note

- The current firmware version does not allow Device Manager to support the Reset

button.

Agent Menu

From the Agent Menu, you can view and edit the system information for the device, or log

into the CLI using Telnet.

System Info

Displays basic system information, including system name, location, contact and
description.

Note

- Device Manager allows the user to enter more than the 50-character limit for

the System Contact, System Name, and System Location parameters. However,

doing so may result in any of the following :

Anywhere from 1 to 12 characters may be truncated from the entered value.

The firmware password may be overwritten if 255 characters are entered for

the System Location parameter. Once this happens, a firmware reload will be

required.

The last 50 characters of the entered value may go into the System Contact

parameter if 255 characters are entered for the System Name parameter.

Note

- Device Manager allows the user to enter multiple-word values for the System

Contact, System Name, and System Location parameters. NULL values are not

allowed.


Management Interface Info

Displays basic interface information for the management port including description,

type, physical address, speed and operation status.


Temperature Info

Displays the temperature of the device in celsius.