App index starting the computation (dx1000 client) – Yokogawa Removable Chassis DX1000N User Manual
Page 79
1-71
IM 04L41B01-17E
Using the Ethernet Interface
1
2
3
4
5
6
App
Index
Starting the Computation (DX1000 Client)
◊ Press
FUNC and select Math start.
The computation starts. A computation icon is displayed on the status display section.
The value of the computation channel 101 in the GROUP 1 of the DX1000 client
varies in conjunction with the measured value of the measurement channel 1 on the
DX1000 server.
Confirming the Communication Status (DX1000 Client)
Showing a Menu to Switch to the Modbus Client Screen
This is the operation to show INFORMATION > MODBUS CLIENT on the display
selection menu.
◊ Press
MENU (to switch to setting mode), and select the Menu tab > Menu customize
>
Display menu.
1. Select
INFORMATION > MODBUS CLIENT using the arrow keys.
* Select
INFORMATION > MODBUS MASTER when you use the Modbus master via the serial
communication.
2. Press the
View soft key.
The selected item displays in white.
View/Hide soft key
Toggles
View and Hide each
time you press the soft key.
3. Press the ESC key to return to the operation screen.
Displaying the Modbus Client Screen
◊ Press
DISP/ENTER and select INFORMATION > MODBUS CLIENT.
* Select
INFORMATION > MODBUS MASTER when you use the Modbus master via the serial
communication.
1.11 Usage Example of the Modbus Function