App index – Yokogawa Removable Chassis DX1000N User Manual
Page 195
4-11
IM 04L41B01-17E
Responses
1
2
3
4
5
6
App
Index
Transmission
(ddd byte):
Data output (where ddd is the number of
data values)
(Login):
Login
(Logout):
Logout
(Disconnected): Forced disconnection (occurs when the
connection was disconnected when
transmitting data using Ethernet).
(Time out):
Timeout, keepalive, TCP retransmission, etc.
E1 nnn:
Single negative response (where
nnn is the
error number)
E2 ee:nnn:
Multiple negative response (where
ee is the
error position and
nnn is the error number)
_ Space
Advanced security (/AS1 option)
• The parameters of commands whose parameters include the user password (EK,
EL, EJ, and LL) are not output.
• Commands performed through the barcode protocol are not logged in the
communication log (operations performed through the barcode protocol are
logged in the operation log).
• Example
The following example shows the log when multiple commands separated by sub
delimiters, “
BO1;???;PS0,” are transmitted. The commands are separated and
output in order with the multiple command flags “
*.”
EA
99/05/11 12:31:11 1 12345678901234567890*> BO1
99/05/11 12:31:11 1 12345678901234567890*< E0
99/05/11 12:31:11 1 12345678901234567890*> ???
99/05/11 12:31:11 1 12345678901234567890*< E2 01:124
99/05/11 12:31:11 1 12345678901234567890*> PS0
99/05/11 12:31:11 1 12345678901234567890*< E0
EN
4.2 Output Format of ASCII Data