App index, Output commands (/as1) – Yokogawa Removable Chassis DX1000N User Manual
Page 132
3-15
IM 04L41B01-17E
Commands
1
2
3
4
5
6
App
Index
Command
Name
Function
Execution
Mode
Setting Connection
Monitor
Connection
Page
WI
Sets the relay operations
B
Yes
No
No
3-58
WF
Sets the Modbus connection limitation
B
Yes
No
No
3-58
WG
Sets an IP address that is allowed to connect via
Modbus
B
Yes
No
No
3-59
WJ
Sets the FTP transfer wait time
B
Yes
No
No
3-59
WQ
Sets PROFIBUS-DP
B
Yes
No
No
3-59
YE
Activates basic settings (cold reset)
Bb
Yes
No
No
3-59
Output Commands (/AS1)
Note
Output commands except BO, CS, and IF cannot be placed in a command sequence.
Command
Name
Function
Execution
Mode
Setting Connection
Monitor
Connection
Page
Administrator User
Control
BO
Sets the byte output order
ALL
Yes
Yes
Yes
3-60
CS
Sets the check sum (can only be used during serial
communication)
ALL
Yes
Yes
Yes
3-60
IF
Sets status filters
ALL
Yes
Yes
Yes
3-60
CB
Sets the data output format
ALL
Yes
Yes
Yes
3-60
CC
Disconnects the Ethernet connection (can only be
used for Ethernet communications)
ALL
Yes
Yes
Yes
3-60
Setup, measurement, and computed data output
FC
Outputs screen image data
ALL
Yes
Yes
Yes
3-61
FE
Outputs setup data
ALL
Yes
Yes
Yes
3-61
FD
Outputs the most recent measured and computed data OSsb
Yes
Yes
Yes
3-61
FF
Outputs FIFO data
OSsb
Yes
Yes
Yes
3-61
FL
Outputs a log, alarm summary, or message summary ALL
Yes
Yes
Yes
3-62
FI
Outputs an operation log
ALL
Yes
Yes
Yes
3-62
IS
Outputs status information
ALL
Yes
Yes
Yes
3-62
FU
Outputs user levels
ALL
Yes
Yes
Yes
3-63
FA
Outputs internal DX information
ALL
Yes
Yes
Yes
3-63
ME
Outputs data stored on the external storage medium
and internal memory
OSsb
Yes
No
No
3-63
MO
Manages and outputs the data stored in the internal
memory
OSsb
Yes
No
No
3-63
Dedicated commands for RS-422/485
Esc O
Opens an instrument
ALL
Yes
Yes
Yes
3-64
Esc C
Closes an instrument
ALL
Yes
Yes
Yes
3-64
Common commands among instruments
*I
Outputs instrument information
ALL
Yes
Yes
Yes
3-65
Maintenance/Test Commands (Available when using the maintenance/test
server function via Ethernet communications)
The administrator is “admin.” The user is “user.”
Command Name
Function
Administrator User
Page
close
Closes another device’s connection
No
No
3-65
con
Outputs connection information
Yes
Yes
3-65
eth
Outputs Ethernet statistics
Yes
Yes
3-65
help
Outputs help
Yes
Yes
3-66
net
Outputs network statistics
Yes
Yes
3-66
quit
Closes the connection to the instrument that you are operating
Yes
Yes
3-66
Instrument Information Output Commands (Available when using the
instrument information server function via Ethernet communications)
Parameter
Function
Page
serial
Outputs the serial number
3-67
host
Outputs the host name
3-67
ip
Outputs the IP address
3-67
3.2 A List of Commands