Basic Setting Commands
• In order to activate the settings that are changed using the basic setting commands,
the settings must be saved using the YE or XE command. Make sure to save
the settings before changing from the basic setting mode to the operation mode.
Otherwise, new settings will not be activated.
• The settings that are returned in response to a query in basic setting mode contain the
new settings even if they are not saved. However, the new settings are not activated
unless they are saved. If the settings are cleared or if you change from basic setting
mode to operation mode before saving the settings, the settings that are returned
in the response to a query contain the settings that were used before they were
changed.
Note
• The settings that are changed using the
YA, YK, RU, YQ, YS, YB, YD, WS, WW,
and
WQ commands are activated after saving the new settings using the XE command and
restarting the DX.
• When you execute the
YE or YO command, communication is disconnected. Commands
listed after the YO or YE command are ignored.
Group Command Function
Execution
Administrator User Page
Name
Mode
WU
Sets the environment
Basic setting mode Yes
No
3-45
WE
Sets calibration management
Basic setting mode
Yes
No
3-47
WO
Sets alarm and DO settings
Basic setting mode Yes
No
3-48
WH
Sets alarm hysteresis
Basic setting mode Yes
No
3-48
XV
Sets the scan interval and A/D integral time
Basic setting mode Yes
No
3-48
XB
Sets burnout detection
Basic setting mode Yes
No
3-49
XJ
Sets RJC
Basic setting mode Yes
No
3-49
XM
Sets memory sampling conditions
Basic setting mode Yes
No
3-49
XT
Sets the temperature unit
Basic setting mode Yes
No
3-49
RF
Sets key lock
Basic setting mode Yes
No
3-49
RN
Sets basic key login
Basic setting mode Yes
No
3-50
RP
Sets user limitations
Basic setting mode Yes
No
3-50
RO
Sets the type of report and when to create reports
Basic setting mode Yes
No
3-51
RM
Sets a report channel
Basic setting mode Yes
No
3-52
XG
Sets the time zone
Basic setting mode Yes
No
3-52
XN
Sets the date format
Basic setting mode Yes
No
3-52
YB
Sets host information
Basic setting mode Yes
No
3-52
YD
Sets network parameters
Basic setting mode Yes
No
3-53
YA
Sets the IP address, subnet mask, and default gateway Basic setting mode Yes
No
3-53
YK
Sets keepalive
Basic setting mode Yes
No
3-53
RU
Sets DNS parameters
Basic setting mode Yes
No
3-53
WS
Sets a server
Basic setting mode Yes
No
3-53
WW
Sets Webpage parameters
Basic setting mode Yes
No
3-53
YQ
Sets communication timeout
Basic setting mode Yes
No
3-53
YT
Sets FTP transfer timing
Basic setting mode Yes
No
3-54
YU
Sets what kind of information to send using e-mail
Basic setting mode Yes
No
3-54
YV
Sets an e-mail recipient address
Basic setting mode Yes
No
3-55
YW
Sets the e-mail sender address
Basic setting mode Yes
No
3-55
YX
Sets the e-mail SNTP server name
Basic setting mode Yes
No
3-55
YJ
Sets the Modbus client’s destination server
Basic setting mode Yes
No
3-55
YP
Sets basic Modbus client settings
Basic setting mode Yes
No
3-55
YR
Sets the Modbus client’s transmit command
Basic setting mode Yes
No
3-55
WB
Sets SNTP client parameters
Basic setting mode Yes
No
3-56
WC
Sets the SNTP operation when memory start is
Basic setting mode Yes
No
3-56
executed
YS
Sets the serial interface
Basic setting mode Yes
No
3-56
3.2 A List of Commands