Basic Setting Commands

• In order to activate the settings that are changed using the basic setting commands,

the settings must be saved using the YE or XE command. Make sure to save
the settings before changing from the basic setting mode to the operation mode.
Otherwise, new settings will not be activated.

• The settings that are returned in response to a query in basic setting mode contain the

new settings even if they are not saved. However, the new settings are not activated
unless they are saved. If the settings are cleared or if you change from basic setting
mode to operation mode before saving the settings, the settings that are returned
in the response to a query contain the settings that were used before they were
changed.

Note

• The settings that are changed using the

YA, YK, RU, YQ, YS, YB, YD, WS, WW,

and

WQ commands are activated after saving the new settings using the XE command and

restarting the DX.

• When you execute the

YE or YO command, communication is disconnected. Commands

listed after the YO or YE command are ignored.

Group Command Function

Execution

Administrator User Page

Name

Mode

WU

Sets the environment

Basic setting mode Yes

No

3-45

WE

Sets calibration management

Basic setting mode

Yes

No

3-47

WO

Sets alarm and DO settings

Basic setting mode Yes

No

3-48

WH

Sets alarm hysteresis

Basic setting mode Yes

No

3-48

XV

Sets the scan interval and A/D integral time

Basic setting mode Yes

No

3-48

XB

Sets burnout detection

Basic setting mode Yes

No

3-49

XJ

Sets RJC

Basic setting mode Yes

No

3-49

XM

Sets memory sampling conditions

Basic setting mode Yes

No

3-49

XT

Sets the temperature unit

Basic setting mode Yes

No

3-49

RF

Sets key lock

Basic setting mode Yes

No

3-49

RN

Sets basic key login

Basic setting mode Yes

No

3-50

RP

Sets user limitations

Basic setting mode Yes

No

3-50

RO

Sets the type of report and when to create reports

Basic setting mode Yes

No

3-51

RM

Sets a report channel

Basic setting mode Yes

No

3-52

XG

Sets the time zone

Basic setting mode Yes

No

3-52

XN

Sets the date format

Basic setting mode Yes

No

3-52

YB

Sets host information

Basic setting mode Yes

No

3-52

YD

Sets network parameters

Basic setting mode Yes

No

3-53

YA

Sets the IP address, subnet mask, and default gateway Basic setting mode Yes

No

3-53

YK

Sets keepalive

Basic setting mode Yes

No

3-53

RU

Sets DNS parameters

Basic setting mode Yes

No

3-53

WS

Sets a server

Basic setting mode Yes

No

3-53

WW

Sets Webpage parameters

Basic setting mode Yes

No

3-53

YQ

Sets communication timeout

Basic setting mode Yes

No

3-53

YT

Sets FTP transfer timing

Basic setting mode Yes

No

3-54

YU

Sets what kind of information to send using e-mail

Basic setting mode Yes

No

3-54

YV

Sets an e-mail recipient address

Basic setting mode Yes

No

3-55

YW

Sets the e-mail sender address

Basic setting mode Yes

No

3-55

YX

Sets the e-mail SNTP server name

Basic setting mode Yes

No

3-55

YJ

Sets the Modbus client’s destination server

Basic setting mode Yes

No

3-55

YP

Sets basic Modbus client settings

Basic setting mode Yes

No

3-55

YR

Sets the Modbus client’s transmit command

Basic setting mode Yes

No

3-55

WB

Sets SNTP client parameters

Basic setting mode Yes

No

3-56

WC

Sets the SNTP operation when memory start is

Basic setting mode Yes

No

3-56

executed

YS

Sets the serial interface

Basic setting mode Yes

No

3-56

3.2 A List of Commands