Server function via ethernet) -67, App index – Yokogawa Removable Chassis DX1000N User Manual
Page 184
3-67
Commands
IM 04L41B01-17E
1
2
3
4
5
6
App
Index
3.12 Instrument Information
Output Commands
(Available when using the
instrument information
server function via
Ethernet)
The instrument information server function interprets one
UDP packet to be one command and returns a single packet
(containing DX information) in response to the command.
Port number
34264/udp
Transfer data
ASCII
Receive buffer size
128
Transmit buffer size
512
Maximum number of parameters 32
In the command packet, you arrange the parameters that
correspond to information you want to receive.
Parameter Description
serial
Outputs the serial number.
host
Outputs the host name (host name that you specified in section 1.3).
ip
Outputs the IP address (the IP address that you specified in section
1.3).
Example Query the IP address and host name. (The first
frame below contains the command packet. The
second frame contains the response packet.)
ip host
EA
ip = 192.168.111.24
host = DX1000-1
EN
Description • Separate each parameter with one or more
spaces (space, tab, carriage return, or line
feed).
• Parameters are not case sensitive.
• Undefined parameters are ignored.
• Parameters after the 32nd parameter are
ignored.
3.12 Instrument Information Output Commands