3.4 Setting Commands

invalid, the DX returns “1.”

• If p4 = MESSAGE and p7 or p8 is invalid, the

DX returns p7 = “1” or p8 = “1.”

Examples are given below.

p1 through p3 are indicated by an ellipsis. The
set values of invalid parameters are bolded.

• When the multi batch function is invalid:

TU...,MEMORYSTART/STOP,

ALL

TU...,DISPLAYGROUPCHANGE,2,

1

TU...,MESSAGE,5,ALL,

1,1

TU...,MESSAGE,5,SELECT,10,

1

• When the multi batch function is valid

TU...,MESSAGE,5,ALL,

1,3

Example Execute memory start with the remote control

input (terminal 1).
TUREMOTE,1,MEMORYSTART

Description • Set various numbers (relay number, internal

switch number, etc.) by referring to the table in
section 3.3.

• You cannot select some of the p4 (action type)

settings depending on the p2 (event type)
setting.

• You cannot select some of the p4 (action type)

settings depending on other DX settings or
depending on the installed options.

• The p4=ALARMDISPLAYRESET setting is

valid when the annunciator function is enabled
and the annunciator sequence is set to ISA-M.

• Set the batch group number by referring to the

table in section 3.3.

• When multi batch /BT2 is in use, p4 is set

to MATHRESET, and p5 is set to ALL, the
calculated values for all computation channels
are reset.

• An event that has “-OFF” attached to it

responds to the logical negation of the
corresponding event that does not have “-OFF”
attached to it. The actions and settings that
the event can support are the same as those
that the corresponding event that does not
have “-OFF” attached to it can support.

• On models with the /AS1 advanced security

option, you cannot set p4 to TRIGGER or
PANELLOAD.

SK

Sets a constant

Syntax

SK p1,p2
p1 Constant number
p2 Constant (-9.9999E+29 to -1.0000E-30, 0,

1.0000E-30 to 9.9999E+29, 5 significant
digits)

Query

SK[p1]?

Example Set the constant in constant number K01 to

1.0000E-10.
SKK01,1.0000E-10

Description • You can use this command on models with the

/M1 or /PM1 math option.

• You cannot use this command while recording

(memory sampling) or computation is in
progress. When using the /BT2 multi batch
option, you cannot use this command if any
of the batch groups is recording (memory
sampling).

• Set p1 by referring to the table in section 3.3.

SI

Sets the rolling average function

of a computation channel

Syntax

SI p1,p2,p3,p4
p1 Computation channel number
p2 Moving average (ON, OFF)
p3 Sampling interval (1S, 2S, 3S, 4S, 5S, 6S,

10S, 12S, 15S, 20S, 30S, 1MIN, 2MIN,
3MIN, 4MIN, 5MIN, 6MIN, 10MIN, 12MIN,
15MIN, 20MIN, 30MIN, 1H)

p4 Number of samples (1 to 1500)

Query

SI[p1]?

Example Turn on the rolling average function of

computation channel 107, set the sampling
interval to 1 minute, and the number of samples
to 20.
SI107,ON,1MIN,20

Description • You can use this command on models with the

/M1 or /PM1 math option.

• Do not set p3 or p4 when p2 is set to OFF.
• Set the sampling interval to a value greater

than the scan interval.

SJ

Sets a TLOG timer

Syntax

SJ p1,p2,p3,p4,p5
p1 Computation channel number
p2 Timer number
p3 Conversion of the unit of time for TLOG.

SUM computation
OFF

Do not convert.

/S

Converts as though the physical
values are integrated in units of
seconds.

/MIN

Converts as though the physical
values are integrated in units of
minutes.

/H

Converts as though the physical
values are integrated in units of
hours.

p4 Reset (ON, OFF)
p5 Timer type

TIMER

Timer

MATCHTIMETIMER

Match time timer

Query

SJ[p1]?

Example Assign timer 1 to computation channel number

110. Do not convert the unit of time and enable
the reset setting.
SJ110,1,OFF,ON,TIMER