Ke performs key operations, Bp supports login (/as1 advanced security option) – Yokogawa Removable Chassis DX1000N User Manual
Page 161
3-44
IM 04L41B01-17E
EE
Switches out of operation mode
(/AS1 advanced security option)
Syntax
EE p1
p1 Mode switch destination (ENG, SYS)
Memory sampling ENG
SYS
In progress
Setting mode during
memory sampling
Basic setting mode
during memory
sampling
Stopped
Setting mode
Basic setting mode
Example Switch to setting mode.
EEENG
BE
Returns to operation mode (/AS1
advanced security option)
Syntax
BE p1
p1 Mode switch operation (END)
Current Mode
END
Setting mode
Returns to operation mode. Creates a setup
file.
Setting mode
during memory
sampling
Returns to operation mode.
BV
Enters a string (can only be used
during serial communication)
Syntax
BV p1,p2
p1 0
p2 Character string (up to 100 characters)
Example Enter “user123.”
BV0,user123
Description • You can use this command to enter character
strings when the DX is displaying the
character input window.
• On models with the /USB1 USB interface
option, this command can be used through the
use of USB barcodes.
• On models with the /AS1 advanced security
option, this command can only be used
through the use of the serial communication
barcode protocol or through a USB barcode
reader.
KE
Performs key operations
Syntax
KE p1
p1 Key
F1 to F7 Soft keys 1 to 7
ESC
ESC key
MENU
MENU key
FUNC
FUNC key
START START key
STOP
STOP key
USER
USER key
FAVORITE Favorite key
0 to 9 Number keys 0 to 9
MINUS The minus key
DOT
The decimal point key
DISP
The DISP/ENTER key
UP
The up arrow key
DOWN
The down arrow key
RIGHT The right arrow key
LEFT
The left arrow key
Example Press the DISP/ENTER key.
KEDISP
Description • This command performs the same operations
as pressing the keys on the DX. When you
send multiple key operations, send them in
the same order that you would perform them
on the DX.
• When you perform this command, it is logged
on the DX as “KEY.” This command is valid
regardless of whether or not the key lock is
on.
• On models with the /AS1 advanced security
option, this command can only be used
through the use of the serial communication
barcode protocol or through a USB barcode
reader.
BP
Supports login (/AS1 advanced
security option)
Syntax
BP p1,p2,p3
p1 Input type
1
User name
2
User name and user ID
p2 User name (up to 20 characters)
p3 User ID (up to 8 characters)
Example Set the user name to “DX.”
BP1,DX
Description • If you execute this command when p1=1, the
DX displays the user ID input window.
• If you execute this command when p1=2, the
DX displays the password input window.
• p3 is valid when p1=2.
• On models with the /AS1 advanced security
option, this command can only be used
through the use of the serial communication
barcode protocol or through a USB barcode
reader.
LL
Logs in through serial
communication (/AS1 advanced
security option)
Syntax
LL p1,p2,p3,p4,p5
p1 User name (up to 20 characters)
p2 User ID (up to 8 characters)
This parameter is meaningless if you are not
using a user ID.
p3 Password (up to 20 characters)
p4 The new password to use if the current one
has expired (up to 20 characters)
This parameter is meaningless if the
current password has not yet expired. This
parameter can be omitted
3.5 Control Commands