App index, Tb sets the bar graph display, Sb sets the bar graph for a channel – Yokogawa Removable Chassis DX1000N User Manual
Page 144: Tn sets a scale, Sv sets a measurement channel’s moving average, Sc sets a channel display color, Ta sets an alarm point mark
3-27
Commands
IM 04L41B01-17E
1
2
3
4
5
6
App
Index
3.4 Setting Commands
Query
TT?
Example Display waveform horizontally, set the message
direction to vertical, and display waveforms by
clearing the current waveforms at memory start.
TTHORIZONTAL,ON,VERTICAL
Description When using the /BT2 multi batch option, p2 is
fixed at ON.
SE
Sets the line width and the
number of grids to use on the
trend graph
Syntax
SE p1,p2
p1 Trend line width (1 to 3) [dots]
p2 Number of grids (4 to 12, AUTO)
Query
SE?
Example Set the trend waveform line width to 1 dot and
the number of grids to 10.
SE1,10
TB
Sets the bar graph display
Syntax
TB p1
p1 Bar graph display direction
HORIZONTAL
VERTICAL
Query
TB?
Example Display the bar graph horizontally.
TBHORIZONTAL
SB
Sets the bar graph for a channel
Syntax
SB p1,p2,p3
p1 Measurement, computation, or external
input channel number
p2 Bar graph base position
NORMAL Normal (lower limit)
CENTER Center
LOWER Lower limit
UPPER Upper limit
p3 Number of scale divisions (4 to 12)
Query
SB[p1]?
Example Set the number of scale divisions on the bar
graph for channel 002 to five, and display the bar
graph from the span lower limit (the scale lower
limit if scale is enabled).
SB002,NORMAL,5
Description You can specify computation channels on
models with the /M1 or /PM1 math option. You
can specify external input channels on models
with the /MC1 external input channel option.
TN
Sets a scale
Syntax
TN p1,p2,p3
p1 Measurement, computation, or external
input channel number
p2 Display position (OFF, 1 to 10)
p3 Number of divisions (4 to 12, C10)
Query
TN[p1]?
Example Set the scale position for channel 003 to 2, and
the number of divisions to 10.
TN003,2,10
SV
Sets a measurement channel’s
moving average
Syntax
SV p1,p2,p3
p1 Measurement channel number
p2 Moving average (OFF, ON)
p3 Number of moving average samples (2 to
400)
Query
SV[p1]?
Example Set the number of moving average samples for
channel 002 to 12.
SV002,ON,12
SC
Sets a channel display color
Syntax
SC p1,p2
p1 Measurement, computation, or external
input channel number
p2 Display color (see SL (sets a trip line))
Query
SC[p1]?
Example Set the channel 002 display color to blue.
SC002,BLUE
Description You can specify computation channels on
models with the /M1 or /PM1 math option. You
can specify external input channels on models
with the /MC1 external input channel option.
TA
Sets an alarm point mark
Syntax
TA p1,p2,p3,p4,p5,p6,p7
p1 Measurement, computation, or external
input channel number
p2 Mark type
ALARM Alarm mark
FIXED Fixed mark
p3 Scale board (ON, OFF)
p4 Alarm level 1 color (AUTO or 24 colors (see
NL; sets a trip line))
AUTO
The same color as the alarm color
p5 Alarm level 2 color (AUTO or 24 colors (see
NL; sets a trip line))
AUTO
The same color as the alarm color
p6 Alarm level 3 color (AUTO or 24 colors (see
NL; sets a trip line))
AUTO
The same color as the alarm color
p7 Alarm level 4 color (AUTO or 24 colors (see
NL; sets a trip line))
AUTO
The same color as the alarm color
Query
TA[p1]?
Example Display alarm marks on the channel 004 scale.
TA004,ALARM,ON