Setting the DX1000 Master (Modbus Master)

Assumes the settings other than those below are left to default values.

Setting the Modbus Master Function

◊ Press

MENU (to switch to setting mode), hold down FUNC for 3 s (to switch to basic

setting mode), and select the

Menu tab > Communication (Serial) > Basic settings.

Item Settings
Address 2
Protocol Modbus-M

Setting Command

◊ Press

MENU (to switch to setting mode), hold down FUNC for 3 s (to switch to basic

setting mode), and select the

Menu tab > Communication (Serial) > Modbus

master > Command settings.

Item Settings
Command type R-M
First and Last C01
Addr. 1
Regi. 30001
Type INT16

Setting the Computation Channel

See “Usage Example of the Modbus Function” in section 1.11.

Assigning the channel to a Group

See “Usage Example of the Modbus Function” in section 1.11.

Starting the Computation

See “Usage Example of the Modbus Function” in section 1.11.

Confirming the Communication Status

See “Usage Example of the Modbus Function” in section 1.11.

2.7 Usage Example of the Modbus Function