3.4 Setting Commands
TO
Sets how the DX operates after
one circular display cycle
Syntax
TO p1
p1 Operation after one cycle
ALLCLEAR Clears the entire waveform
display and starts drawing a
new waveform.
DIVCLEAR Clears a section of the
waveform display and starts
drawing a new waveform.
Query
TO?
Example Set the operation after one cycle to all clear.
TOALLCLEAR
TW
Sets the secondary trend interval
Syntax
TW p1
p1 Trend interval (5S, 10S, 15S, 30S, 1MIN,
2MIN, 5MIN, 10MIN, 15MIN, 20MIN, 30MIN,
1H, 2H, 4H, 10H)
Query
TW?
Example Set the interval to 2 minutes.
TW2MIN
Description • Set the trend interval (p1) to a value less than
the scan interval.
• You can only set the trend interval (p3) to 5S
and 10S for high-speed input models (DX1002,
DX1002N, DX1004, DX1004N, DX2004,and
DX2008).
• You can only set the trend interval (p3) on
medium-speed models to 15S if fast sampling
mode is enabled.
• You cannot use this command when multi
batch /BT2 is enabled.
TM
Sets manual sampling
Syntax
TM p1,p2,p3
p1 Manual sample number
p2 Enable or disable (ON or OFF)
p3 Measurement, computation, or external
input channel number
Query
TM[p1]?
Example Assign measurement channel 002 to manual
sample number 001.
TM001,ON,002
Description • You can use this command on models with the
/MC1 external input channel option.
• You can specify computation channels on
models with the /M1 or /PM1 math option.
TE
Sets the sampling conditions for
event data
Syntax
TE p1,p2,p3,p4,p5,p6
p1 1
p2 Sample interval (25MS, 125MS, 250MS,
500MS, 1S, 2S, 5S, 10S, 30S, 1MIN, 2MIN,
5MIN, 10MIN, 15MIN, 20MIN, 30MIN)
p3 Sample mode
FREE
Starts data acquisition at memory
start and stops data acquisition at
memory stop.
SINGLETRIGGER
Acquires data once
for a specified time length after the
trigger occurs and then stops.
REPEATTRIGGER
Acquires data for
a specified time length after the
trigger occurs and then enters the
trigger wait condition.
p4 Sample time length (10MIN, 20MIN, 30MIN,
1H, 2H, 3H, 4H, 6H, 8H, 12H, 1DAY, 2DAY,
3DAY, 5DAY, 7DAY, 10DAY, 14DAY, 31DAY)
p5 Pretrigger length as percentage (0, 5, 25,
50, 75, 95, 100)
p6 Key trigger source disable or enable (OFF
or ON)
Parameters p5 to p6 are valid when p3 is set to
SINGLETRIGGER or REPEATTRIGGER.
Query
TE[p1]?
Example Acquire data at a sampling rate of 125 ms for 10
minutes using single trigger mode.
TE1,125MS,SINGLETRIGGER,10MIN
Description • You cannot choose a sample interval that is
shorter than the scan interval.
• You cannot use this command while recording
(memory sampling) in progress. If you are
using the /BT2 multi batch option, you cannot
use this command if any of the batch groups
is recording (memory sampling).
• You cannot set SINGLETRIGGER or
REPEATTRIGGER as a sample mode when
multi batch /BT2 is enabled.
• On models with the /AS1 advanced security
option, you cannot set p3 to SINGLETRIGGER
or REPEATTRIGGER.
SZ
Sets a zone
Syntax
SZ p1,p2,p3
p1 Measurement, computation, or external
input channel number
p2 Lower zone boundary position (0 to 95) [%]
p3 Upper zone boundary position (5 to 100) [%]
Query
SZ[p1]?
Example Display channel 002 in a zone between 30% and
50%.
SZ002,30,50
Description • You can specify computation channels on
models with the /M1 or /PM1 math option. You
can specify external input channels on models
with the /MC1 external input channel option.
• Set the boundary positions as percentages
of the entire amplitude axis in the waveform