beautypg.com

App index, Tw sets the secondary trend interval, Tm sets manual sampling – Yokogawa Removable Chassis DX1000N User Manual

Page 140: Te sets the sampling conditions for event data, Sz sets a zone

background image

3-23

Commands

IM 04L41B01-17E

1

2

3

4

5

6

App

Index

3.4 Setting Commands

TO

Sets how the DX operates after

one circular display cycle

Syntax

TO p1
p1 Operation after one cycle

ALLCLEAR Clears the entire waveform

display and starts drawing a
new waveform.

DIVCLEAR Clears a section of the

waveform display and starts
drawing a new waveform.

Query

TO?

Example Set the operation after one cycle to all clear.

TOALLCLEAR

TW

Sets the secondary trend interval

Syntax

TW p1
p1 Trend interval (5S, 10S, 15S, 30S, 1MIN,

2MIN, 5MIN, 10MIN, 15MIN, 20MIN, 30MIN,
1H, 2H, 4H, 10H)

Query

TW?

Example Set the interval to 2 minutes.

TW2MIN

Description • Set the trend interval (p1) to a value less than

the scan interval.

• You can only set the trend interval (p3) to 5S

and 10S for high-speed input models (DX1002,
DX1002N, DX1004, DX1004N, DX2004,and
DX2008).

• You can only set the trend interval (p3) on

medium-speed models to 15S if fast sampling
mode is enabled.

• You cannot use this command when multi

batch /BT2 is enabled.

TM

Sets manual sampling

Syntax

TM p1,p2,p3
p1 Manual sample number
p2 Enable or disable (ON or OFF)
p3 Measurement, computation, or external

input channel number

Query

TM[p1]?

Example Assign measurement channel 002 to manual

sample number 001.
TM001,ON,002

Description • You can use this command on models with the

/MC1 external input channel option.

• You can specify computation channels on

models with the /M1 or /PM1 math option.

TE

Sets the sampling conditions for

event data

Syntax

TE p1,p2,p3,p4,p5,p6
p1 1

p2 Sample interval (25MS, 125MS, 250MS,

500MS, 1S, 2S, 5S, 10S, 30S, 1MIN, 2MIN,
5MIN, 10MIN, 15MIN, 20MIN, 30MIN)

p3 Sample mode

FREE

Starts data acquisition at memory
start and stops data acquisition at
memory stop.

SINGLETRIGGER

Acquires data once

for a specified time length after the
trigger occurs and then stops.

REPEATTRIGGER

Acquires data for

a specified time length after the
trigger occurs and then enters the
trigger wait condition.

p4 Sample time length (10MIN, 20MIN, 30MIN,

1H, 2H, 3H, 4H, 6H, 8H, 12H, 1DAY, 2DAY,
3DAY, 5DAY, 7DAY, 10DAY, 14DAY, 31DAY)

p5 Pretrigger length as percentage (0, 5, 25,

50, 75, 95, 100)

p6 Key trigger source disable or enable (OFF

or ON)

Parameters p5 to p6 are valid when p3 is set to
SINGLETRIGGER or REPEATTRIGGER.

Query

TE[p1]?

Example Acquire data at a sampling rate of 125 ms for 10

minutes using single trigger mode.
TE1,125MS,SINGLETRIGGER,10MIN

Description • You cannot choose a sample interval that is

shorter than the scan interval.

• You cannot use this command while recording

(memory sampling) in progress. If you are
using the /BT2 multi batch option, you cannot
use this command if any of the batch groups
is recording (memory sampling).

• You cannot set SINGLETRIGGER or

REPEATTRIGGER as a sample mode when
multi batch /BT2 is enabled.

• On models with the /AS1 advanced security

option, you cannot set p3 to SINGLETRIGGER
or REPEATTRIGGER.

SZ

Sets a zone

Syntax

SZ p1,p2,p3
p1 Measurement, computation, or external

input channel number

p2 Lower zone boundary position (0 to 95) [%]
p3 Upper zone boundary position (5 to 100) [%]

Query

SZ[p1]?

Example Display channel 002 in a zone between 30% and

50%.
SZ002,30,50

Description • You can specify computation channels on

models with the /M1 or /PM1 math option. You
can specify external input channels on models
with the /MC1 external input channel option.

• Set the boundary positions as percentages

of the entire amplitude axis in the waveform

This manual is related to the following products: