Analog signal, Low voltage scale, High voltage scale – Watlow Series PD User Manual
Page 94: Low current scale, High current scale, Offset, Shifts the retransmit output signal up or down
W a t l o w S e r i e s P D
■
92
■
C h a p t e r 9 D e v i c e C o n f i g T a b l e
Parameter Name
and Description
Web Page
Your
Settings
Range
Default
Modbus*
(Read/write and
scaling)
Output 1 - Analog TypeSelect analog output type.,Configuration Output 1,,Voltage (0)Current (1),Voltage (0),409 (R/W)
Output 1 - mA Low ScaleSet unit value for low end of current range. This setting determines range of output.,Configuration Output 1,,0 to
20000,4000,410-411 (R/W) (/1000)
Output 1 - mA High ScaleSet unit value for high end of current range. This setting determines range of output.,Configuration Output 1,,0
to 20000,20000,412-413 (R/W) (/1000)
Output 1 - V Low ScaleSet unit value for low end of voltage range. This setting determines range of output.,Configuration Output 1,,0 to
10000,0,414-415 (R/W) (/1000)
Output 1 - V High ScaleSet unit value for high end of voltage range. This setting determines range of output.,Configuration Output 1,,0 to
10000,10000,416-417 (R/W) (/1000)
Output 1 - Retransmit SourceSelect which source output 1 will retransmit.,Configuration Output 1,,Process Value 1 (0)Process Value 2
(2)Set Point 1 (1)Set Point 2 (3),Process Value 1 (0),422 (R/W)
Output 1 - Retransmit Low ScaleSet low end of current or voltage range to retransmit.,Configuration Output 1,,-2000000200 to
2000000200,-2000000200,423-424 (R/W) (/1000)
Output 1 - Retransmit High ScaleSet high end of current or voltage range to retransmit.,Configuration Output 1,,-2000000200 to
2000000200,2000000200,425-426 (R/W) (/1000)
Output 1 - StateDisplay state of output.,Trend Information,,Inactive (0)Active (1),Inactive (0),397 (R)
Output 1 - Analog Type
Select analog output type.
Configuration Output 1
Voltage (0)
Current (1)
Voltage (0)
409 (R/W)
Output 1 - Current Low Scale
Set unit value for low end of
current range. This setting
determines range of output.
Configuration Output 1
0 to 20000 units
4000
410-411 (R/W)
(/1000)
Output 1 - Current High Scale
Set unit value for high end of
current range. This setting
determines range of output.
Configuration Output 1
0 to 20000 units
20000
412-413 (R/W)
(/1000)
Output 1 - Voltage Low Scale
Set unit value for low end of
voltage range. This setting
determines range of output.
Configuration Output 1
0 to 10000 units
0
414-415 (R/W)
(/1000)
Output 1 - Voltage High Scale
Set unit value for high end of
voltage range. This setting
determines range of output.
Configuration Output 1
0 to 10000 units
10000
416-417 (R/W)
(/1000)
Output 1 - Retransmit Source
Select which source Output 1
will retransmit.
Configuration Output 1
Process Value 1 (0)
Process Value 2 (2)
Set Point 1 (1)
Set Point 2 (3)
Process Value
1 (0)
422 (R/W)
Output 1 - Retransmit
Low Scale
Set low end of the current or
voltage range for the retrans-
mit signal.
Configuration Output 1
-2000000200 to 2000000200
degrees or units
-2000000200
423-424 (R/W)
(/1000)
Output 1 - Retransmit
High Scale
Set high end of the current or
voltage range for the retrans-
mit signal.
Configuration Output 1
-2000000200 to 2000000200
degrees or units
2000000200
425-426 (R/W)
(/1000)
Output 1 - Retransmit Offset
Set the offset value for the re-
transmit signal.
Configuration Output 1
-9999000 to 9999000 de-
grees or units
0
427-428 (R/W)
(/1000)
Output 1 - State
Display state of output.
Monitor Device
Inactive (0)
Active (1)
Inactive (0)
397 (R)