W a t l o w S e r i e s P D
■
88
■
C h a p t e r 9 D e v i c e C o n f i g T a b l e
Device Configuration > Control Loops > Loop 2 > PID Set 4
Loop 2 - PID Set 4, Indirect Prop BandPID Set 4 - Set the heat (indirect) proportional band from set point in process units.,Configuration
Multiple PID Sets 2,,1000 to 999000,25000,847-848 (R/W) (/1000)
Loop 2 - PID Set 4, Indirect IntegralPID Set 4 - Set the heat (indirect) integral in minutes per repeat.,Configuration Multiple PID Sets 2,,0
to 99990,0,849-850 (R/W) (/1000)
Loop 2 - PID Set 4, Indirect DerivativePID Set 4 - Set the heat (indirect) derivative time in minutes.,Configuration Multiple PID Sets 2,,0 to
9990,0,851-852 (R/W) (/1000)
Loop 2 - PID Set 4, Indirect Dead BandPID Set 4 - Set the offset of the heat (indirect) proportional band from set point in process
units.,Configuration Multiple PID Sets 2,,0 to 999000,0,845-846 (R/W) (/1000)
Loop 2 - PID Set 4, Direct Prop BandPID Set 4 - Set the cool (direct) proportional band from set point in process units.,Configuration Multi-
ple PID Sets 2,,1000 to 999000,25000,855-856 (R/W) (/1000)
Loop 2 - PID Set 4, Direct IntegralPID Set 4 - Set the cool (direct) integral in minutes per repeat.,Configuration Multiple PID Sets 2,,0 to
99990,0,857-858 (R/W) (/1000)
Loop 2 - PID Set 4, Direct DerivativePID Set 4 - Set the cool (direct) derivative time in minutes.,Configuration Multiple PID Sets 2,,0 to
9990,0,859-860 (R/W) (/1000)
Loop 2 - PID Set 4, Direct DeadbandPID Set 4 - Set the offset of the cool (direct) proportional band from set point in process units.,Configu-
ration Multiple PID Sets 2,,0 to 999000,0,853-854 (R/W) (/1000)
Loop 2 - PID Set 4 Crossover PointSet crossover value to switch from PID Set 4 to PID Set 5.,Configuration Loop Settings 2,,-30000000 to
30000000,30000000,795-796 (R/W) (/1000)
Parameter Name
and Description
Web Page
Your
Settings
Range
Default
Modbus*
(Read/write and
scaling)
Loop 2 - PID Set 4 Indirect
Prop Band
Set the heat (indirect) propor-
tional band from set point in
process units.
Configuration Multiple
PID Sets 2
1000 to 999000 degrees or
units
25000
847-848 (R/W)
(/1000)
Loop 2 - PID Set 4 Indirect
Integral
Set the heat (indirect) inte-
gral in minutes per repeat.
Configuration Multiple
PID Sets 2
0 to 99990 minutes
0
849-850 (R/W)
(/1000)
Loop 2 - PID Set 4 Indirect
Derivative
Set the heat (indirect) deriva-
tive time in minutes.
Configuration Multiple
PID Sets 2
0 to 9990 minutes
0
851-852 (R/W)
(/1000)
Loop 2 - PID Set 4 Indirect
Dead Band
Set the offset of the heat
(indirect) proportional band
from set point in process
units.
Configuration Multiple
PID Sets 2
0 to 999000 degrees or units 0
845-846 (R/W)
(/1000)
Loop 2 - PID Set 4 Direct
Prop Band
Set the cool (direct) propor-
tional band from set point in
process units.
Configuration Multiple
PID Sets 2
1000 to 999000 degrees or
units
25000
855-856 (R/W)
(/1000)
Loop 2 - PID Set 4 Direct
Integral
Set the cool (direct) integral
in minutes per repeat.
Configuration Multiple
PID Sets 2
0 to 99990 minutes
0
857-858 (R/W)
(/1000)
Loop 2 - PID Set 4 Direct
Derivative
Set the cool (direct) derivative
time in minutes.
Configuration Multiple
PID Sets 2
0 to 9990 minutes
0
859-860 (R/W)
(/1000)
Loop 2 - PID Set 4 Direct
Dead Band
Set the offset of the cool
(direct) proportional band
from set point in process
units.
Configuration Multiple
PID Sets 2
0 to 999000 degrees or units 0
853-854 (R/W)
(/1000)
Loop 2 - PID Set 4 Crossover
Point
Set crossover value to switch
from PID Set 4 to PID Set 5.
Configuration Loop
Settings 2
-30000000 to 30000000 de-
grees or units
30000000
795-796 (R/W)
(/1000)