Name and Description

Web Page

Range (Scaling)

Iterations

Default

EIP Decimal (Hex)

Modbus

EIP Data Type

Access

Ramp Action
Select what event(s) trigger a ramp to set point.

Control Loop {1 or 2}

Configuration

Off (0)

Startup (1)

SP Change (2)

Startup and SP Change

(3)

Loop 1
Loop 2

Off (0)

106/1/58 (6A/1/3A)
106/2/58 (6A/2/3A)

757
877

UINT

R/W

Ramp Rate
Set the interval of degrees or units that the
ramping set point will change per minute or hour,
as determined by the Ramp Interval setting.

Control Loop {1 or 2}

Configuration

0 to 9,999,000 (/1000)

Loop 1
Loop 2

100,000

106/1/60 (6A/1/3C)
106/2/60 (6A/2/3C)

759-760
879-880

DINT

R/W

Ramp Interval
Select the time unit that applies to the Ramp Rate
parameter.

Control Loop {1 or 2}

Configuration

Minute (0)

Hour (1)

Loop 1
Loop 2

Minute (0)

106/1/59 (6A/1/3B)
106/2/59 (6A/2/3B)

758
878

UINT

R/W

Device Configuration > Control Loops > Loop {1 or 2} Multiple PID Sets
Cross Over Source
Specify whether to switch the PID sets based on
the set point or process value.

Multiple PID Loop {1 or

2} Configuration

Process Value (0)

Set Point (1)

Loop 1
Loop 2

Process Value (0)

106/1/13 (6A/1/D)
106/2/13 (6A/2/D)

668
788

UINT

R/W

Heat (Indirect) Propband
Set the heat (indirect) proportional band in process
units.

Multiple PID Loop {1 or

2} Configuration

1,000 to 999,000 (/1000)

Loop 1 Set 1
Loop 1 Set 2
Loop 1 Set 3
Loop 1 Set 4
Loop 1 Set 5
Loop 2 Set 1
Loop 2 Set 2
Loop 2 Set 3
Loop 2 Set 4
Loop 2 Set 5

25,000

106/1/19 (6A/1/13)

106/1/27 (6A/1/1B)

106/1/35 (6A/1/23)

106/1/43 (6A/1/2B)

106/1/51 (6A/1/33)
106/2/19 (6A/2/13)

106/2/27 (6A/2/1B)

106/2/35 (6A/2/23)

106/2/43 (6A/2/2B)

106/2/51 (6A/2/33)

679-680
695-696
711-712
727-728
743-744
799-800
815-816
831-832
847-848
863-864

DINT

R/W

Heat (Indirect) Integral
Set the heat (indirect) integral in minutes per
repeat.

Multiple PID Loop {1 or

2} Configuration

0 to 99,990 (/1000)

Loop 1 Set 1
Loop 1 Set 2
Loop 1 Set 3
Loop 1 Set 4
Loop 1 Set 5
Loop 2 Set 1
Loop 2 Set 2
Loop 2 Set 3
Loop 2 Set 4
Loop 2 Set 5

0

106/1/20 (6A/1/14)

106/1/28 (6A/1/1C)

106/1/36 (6A/1/24)

106/1/44 (6A/1/2C)

106/1/52 (6A/1/34)
106/2/20 (6A/2/14)

106/2/28 (6A/2/1C)

106/2/36 (6A/2/24)

106/2/44 (6A/2/2C)

106/2/52 (6A/2/34)

681-682
697-698
713-714
729-730
745-746
801-802
817-818
833-834
849-850
865-866

DINT

R/W

Heat (Indirect) Derivative
Set the heat (indirect) derivative time in minutes.

Multiple PID Loop {1 or

2} Configuration

0 to 9,990 (/1000)

Loop 1 Set 1
Loop 1 Set 2
Loop 1 Set 3
Loop 1 Set 4
Loop 1 Set 5
Loop 2 Set 1
Loop 2 Set 2
Loop 2 Set 3
Loop 2 Set 4
Loop 2 Set 5

0

106/1/21 (6A/1/15)

106/1/29 (6A/1/1D)

106/1/37 (6A/1/25)

106/1/45 (6A/1/2D)

106/1/53 (6A/1/35)
106/2/21 (6A/2/15)

106/2/29 (6A/2/1D)

106/2/37 (6A/2/25)

106/2/45 (6A/2/2D)

106/2/53 (6A/2/35)

683-684
699-700
715-716
731-732
747-748
803-804
819-820
835-836
851-852
867-868

DINT

R/W

SERIES PD with EtherNet/IP

Addressing Information (rev c) 175