Device Configuration > Control Loops > Loop 1 > PID Set 5

Loop 1 - PID Set 5, Indirect Prop BandPID Set 5 - Set the heat (indirect) proportional band from set point in process units.,Configuration
Multiple PID Sets 1,,1000 to 999000,25000,743-744 (R/W) (/1000)
Loop 1 - PID Set 5, Indirect IntegralPID Set 5 - Set the heat (indirect) integral in minutes per repeat.,Configuration Multiple PID Sets 1,,0
to 99990,0,745-746 (R/W) (/1000)
Loop 1 - PID Set 5, Indirect DerivativePID Set 5 - Set the heat (indirect) derivative time in minutes.,Configuration Multiple PID Sets 1,,0 to
9990,0,747-748 (R/W) (/1000)
Loop 1 - PID Set 5, Indirect Dead BandPID Set 5 - Set the offset of the heat (indirect) proportional band from set point in process
units.,Configuration Multiple PID Sets 1,,0 to 999000,0,741-742 (R/W) (/1000)
Loop 1 - PID Set 5, Direct Prop BandPID Set 5 - Set the cool (direct) proportional band from set point in process units.,Configuration Multi-
ple PID Sets 1,,1000 to 999000,25000,751-752 (R/W) (/1000)
Loop 1 - PID Set 5, Direct IntegralPID Set 5 - Set the cool (direct) integral in minutes per repeat.,Configuration Multiple PID Sets 1,,0 to
99990,0,753-754 (R/W) (/1000)
Loop 1 - PID Set 5, Direct DerivativePID Set 5 - Set the cool (direct) derivative time in minutes.,Configuration Multiple PID Sets 1,,0 to
9990,0,755-756 (R/W) (/1000)
Loop 1 - PID Set 5, Direct Dead BandPID Set 5 - Set the offset of the cool (direct) proportional band from set point in process units.,Config-
uration Multiple PID Sets 1,,0 to 999000,0,749-750 (R/W) (/1000)

Parameter Name

and Description

Web Page

Your

Settings

Range

Default

Modbus*

(Read/write and

scaling)

Loop 1 - PID Set 5 Indirect
Prop Band

Set the heat (indirect) propor-
tional band from set point in
process units.

Configuration Multiple
PID Sets 1

1000 to 999000 degrees or
units

25000

743-744 (R/W)
(/1000)

Loop 1 - PID Set 5 Indirect
Integral

Set the heat (indirect) integral
in minutes per repeat.

Configuration Multiple
PID Sets 1

0 to 99990 minutes

0

745-746 (R/W)
(/1000)

Loop 1 - PID Set 5 Indirect
Derivative

Set the heat (indirect) deriva-
tive time in minutes.

Configuration Multiple
PID Sets 1

0 to 9990 minutes

0

747-748 (R/W)
(/1000)

Loop 1 - PID Set 5 Indirect
Dead Band

Set the offset of the heat (indi-
rect) proportional band from
set point in process units.

Configuration Multiple
PID Sets 1

0 to 999000 degrees or units 0

741-742 (R/W)
(/1000)

Loop 1 - PID Set 5 Direct
Prop Band

Set the cool (direct) propor-
tional band from set point in
process units.

Configuration Multiple
PID Sets 1

1000 to 999000 degrees or
units

25000

751-752 (R/W)
(/1000)

Loop 1 - PID Set 5 Direct
Integral

Set the cool (direct) integral in
minutes per repeat.

Configuration Multiple
PID Sets 1

0 to 99990 minutes

0

753-754 (R/W)
(/1000)

Loop 1 - PID Set 5 Direct
Derivative

Set the cool (direct) derivative
time in minutes.

Configuration Multiple
PID Sets 1

0 to 9990 minutes

0

755-756 (R/W)
(/1000)

Loop 1 - PID Set 5 Direct
Dead Band

Set the offset of the cool (di-
rect) proportional band from
set point in process units.

Configuration Multiple
PID Sets 1

0 to 999000 degrees or units 0

749-750 (R/W)
(/1000)