Name and Description
Web Page
Range (Scaling)
Iterations
Default
EIP Decimal (Hex)
Modbus
EIP Data Type
Access
High Current Scale
Set the input process current (in milliamps) that will
correspond to the High Process Scale.
Analog Input {1 or 2}
Configuration
0 to 20,000 (/1000)
Analog Input 1
Analog Input 2
20000
102/1/5 (66/1/5)
102/2/5 (66/2/5)
256-257
286-287
DINT
R/W
Temperature Process Value Units
Indicates the temperature units displayed in the
web pages for a thermocouple and RTD input.
This can be set in the web page.
Analog Input {1 or 2}
Configuration
Fahrenheit (0)
Celsius (1)
Analog Input 1
Analog Input 2
Fahrenheit (0)
108/1/35 (6C/1/23)
108/1/39 (6C/1/27)
1109
1120
UINT
R
Temperature Process Value Precision
Indicates the number of decimal places displayed
in the web pages for a thermocouple or RTD input.
This can be set in the web page.
Analog Input {1 or 2}
Configuration
0 (0)
0.0 (1)
Analog Input 1
Analog Input 2
0 (0)
108/1/33 (6C/1/21)
108/1/37 (6C/1/25)
1107
1118
UINT
R
Filter Method
Select a filter method to smooth out a rapidly
changing input signal.
Analog Input {1 or 2}
Configuration
Off (0)
First Order (1)
Analog Input 1
Analog Input 2
Off (0)
102/1/11 (66/1/B)
102/2/11 (66/2/B)
268
298
UINT
R/W
Filter Time Base
Set the filter time. A higher value will smooth out
the signal more.
Analog Input {1 or 2}
Configuration
100 to 60,000 (/1000)
Analog Input 1
Analog Input 2
100
102/1/12 (66/1/C)
102/2/12 (66/2/C)
269-270
DINT
R/W
Single Offset Value
Set a value to compensate for the input's lead
resistance and sensor inaccuracy.
Analog Input {1 or 2}
Configuration
-9,999,000 to 9,999,000
(/1000)
Analog Input 1
Analog Input 2
0
102/1/10 (66/1/A)
102/2/10 (66/2/A)
266-267
296-297
DINT
R/W
Device Configuration > Inputs > CT Input {3 or 4}
Function
Set whether to enable the CT input.
CT Input {3 or 4}
Configuration
Off (0)
CT Current (6)
CT Input 3
CT Input 4
Off (0)
102/3/1 (66/3/1)
102/4/1 (66/4/1)
311
331
UINT
R/W
CT Precision
Indicates the number of decimal places displayed
in the web page for CT inputs. This can be set in
the web page.
CT Input {3 or 4}
Configuration
0 (0)
0.0 (1)
0.00 (2)
0.000 (3)
CT Input 3
CT Input 4
0 (0)
108/1/42 (6C/1/2A)
108/1/46 (6C/1/2E)
1124
1128
UINT
R
CT Units
Indicates the units displayed in the web page for
CT inputs. This can be set in the web page
CT Input {3 or 4}
Configuration
Up to four alphanumeric
characters
CT Input 3
CT Input 4
108/1/44 (6C/1/2C)
108/1/48 (6C/1/30)
1125-1126
1129-1130
SHORT_STRING
R
Low CT Scale
Set the value that will be displayed when the
current transformer (CT) input is at its minimum,
as determined by the Low Current Scale.
CT Input {3 or 4}
Configuration
-30,000,000 to 30,000,000
(/1000)
CT Input 3
CT Input 4
-30,000,000
102/3/8 (66/3/8)
102/4/8 (66/4/8)
316-317
336-337
DINT
R/W
High CT Scale
Set the value that will be displayed when the
current transformer (CT) input is at its maximum,
as determined by the High Current Scale.
CT Input {3 or 4}
Configuration
-30,000,000 to 30,000,000
(/1000)
CT Input 3
CT Input 4
30,000,000
102/3/9 (66/3/9)
102/4/9 (66/4/9)
318-319
338-339
DINT
R/W
Low Current Scale
Set the input process current (in milliamps) that will
correspond to the Low CT Scale.
CT Input {3 or 4}
Configuration
0 to 50,000 (/1000)
CT Input 3
CT Input 4
0
102/3/4 (66/3/4)
102/4/4 (66/4/4)
312-313
332-333
DINT
R/W
High Current Scale
Set the input process current (in milliamps) that will
correspond to the High CT Scale.
CT Input {3 or 4}
Configuration
0 to 50,000 (/1000)
CT Input 3
CT Input 4
20,000
102/3/5 (66/3/5)
102/4/5 (66/4/5)
314-315
334-335
DINT
R/W
Output
Select output to monitor with the CT input.
CT Input {3 or 4}
Configuration
Output 1 (0)
Output 2 (1)
Output 3 (2)
Output 4 (3)
CT Input 3
CT Input 4
Output 2 (1)
102/3/13 (66/3/D)
102/4/13 (66/4/D)
322
342
UINT
R/W
Single Offset Value
Set a value to compensate for the input's lead
resistance and signal inaccuracy.
CT Input {3 or 4}
Configuration
-9,999,000 to 9,999,000
(/1000)
CT Input 3
CT Input 4
0
102/3/10 (66/3/A)
102/4/10 (66/4/A)
320-321
340-341
DINT
R/W