beautypg.com

Watlow Series PD User Manual

Page 181

background image

Name and Description

Web Page

Range (Scaling)

Iterations

Default

EIP Decimal (Hex)

Modbus

EIP Data Type

Access

Output Logic Operator
Select the logic operation to determine the event
output status.

Output {1 to 4}

Configuration

And (0)

Or (1)

Output 1
Output 2
Output 3
Output 4

And (0)

104/1/7 (68/1/7)
104/2/7 (68/2/7)
104/3/7 (68/3/7)
104/4/7 (68/4/7)

399
439
469
509

UINT

R/W

Output Active State
Select the output state when an alarm condition is
true.

Output {1 to 4}

Configuration

Energized (0)

De-Energized (1)

Output 1
Output 2
Output 3
Output 4

Energized (0)

104/1/18 (68/1/12)
104/2/18 (68/2/12)
104/3/18 (68/3/12)
104/4/18 (68/4/12)

408
448
478
518

UINT

R/W

Output State
Indicates the state of the output.

Inactive (0)

Active (1)

Output 1
Output 2
Output 3
Output 4

Inactive (0)

104/1/5 (68/1/5)
104/2/5 (68/2/5)
104/3/5 (68/3/5)
104/4/5 (68/4/5)

397
437
467
507

UINT

R

Device Configuration > Alarms > Alarm {1 to 8}
Alarm Type
Select the type of alarm. A process alarm
responds when the temperature crosses a fixed
value. A deviation alarm responds when the
termperature deviates from the controlled setpoint
by the Alarm Deviation Set Point.

Alarm {1 to 8}

Configuration

Off (0)

Low Process (1)

High Process (2)

Low Deviation (3)

High Deviation (4)

Low CT (5)

High CT (6)

Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8

Off (0)

105/1/1 (69/1/1)
105/2/1 (69/2/1)
105/3/1 (69/3/1)
105/4/1 (69/4/1)
105/5/1 (69/5/1)
105/6/1 (69/6/1)
105/7/1 (69/7/1)
105/8/1 (69/8/1)

531
545
559
573
587
601
615
629

UINT

R/W

Process Alarm Source
Select which process value the alarm will monitor.

Alarm {1 to 8}

Configuration

Process Value 1 (0)
Process Value 2 (1)

Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8

Process Value 1

(0)

105/1/2 (69/1/2)
105/2/2 (69/2/2)
105/3/2 (69/3/2)
105/4/2 (69/4/2)
105/5/2 (69/5/2)
105/6/2 (69/6/2)
105/7/2 (69/7/2)
105/8/2 (69/8/2)

532
546
560
574
588
602
616
630

UNIT

R/W

Process Alarm Set Point
Set the temperature or process value that will
trigger the alarm.

Alarm {1 to 8}

Configuration

-30,000,000 to 30,000,000

(/1000)

Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8

0

101/1/49 (65/1/31)
101/1/55 (65/1/37)

101/1/61 (65/1/3D)

101/1/67 (65/1/43)
101/1/73 (65/1/49)
101/1/79 (65/1/4F)
101/1/85 (65/1/55)

101/1/91 (65/1/5B)

106-107
119-120
132-133
145-146
158-159
171-172
184-185
197-198

DINT

R/W

Deviation From Loop
Select which set point the alarm will monitor.

Alarm {1 to 8}

Configuration

Loop 1 (0)
Loop 2 (1)

Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8

Loop 1 (0)

105/1/3 (69/1/3)
105/2/3 (69/2/3)
105/3/3 (69/3/3)
105/4/3 (69/4/3)
105/5/3 (69/5/3)
105/6/3 (69/6/3)
105/7/3 (69/7/3)
105/8/3 (69/8/3)

533
547
561
575
589
603
617
631

UINT

R/W

Deviation Alarm Set Point
Set the deviation from the set point that will trigger
an alarm.

Alarm {1 to 8}

Configuration

-30,000,000 to 30,000,000

(/1000)

Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8

1

101/1/48 (65/1/30)
101/1/54 (65/1/36)

101/1/60 (65/1/3C)

101/1/66 (65/1/42)
101/1/72 (65/1/48)

101/1/78 (65/1/4E)

101/1/84 (65/1/54)

101/1/90 (65/1/5A)

104-105
117-118
130-131
143-144
156-157
169-170
182-183
195-196

DINT

R/W

SERIES PD with EtherNet/IP

Addressing Information (rev c) 179