beautypg.com

Miscellaneous setup (misc) page – Yamaha DME User Manual

Page 494

background image

Chapter 6 Component Guide

DME Designer Owner’s Manual

494

2 Panel Lock Boot

Determines whether or not panel lock will be on when
power to the device is turned on. This parameter can
be set to “Unlock” or “Lock.”

Unlock: Panel lock is OFF when power to the
device is turned on.
Lock: Panel lock is ON when power to the device is
turned on.

3 Panel Lock Target

Displays the controls (control functions) to be affected
by panel lock. Panel Lock Target status of ICP1 is fix
to “Key Only.”

4 User Defined Lock

Sets the lock status individually for each of the four
User Defined Button pages.

ON: The corresponding User Defined Button will
not appear on the display.
OFF: The corresponding User Defined Button will
appear on the display.

To change the settings use the [F1] and [F3] keys to
move the cursor to the setting for the desired page,
the press the [ENTER] button to alternately turn the
setting “ON” and “OFF.”

Miscellaneous Setup (Misc)
Page

This page includes parameters not available in any
other page.

1 Scene Store

Determines whether or not scene store operations are
allowed. This parameter can be set to “Enable” or
“Disable.”

Enable: Scene store operations are allowed.
Disable: Scene store operations are prohibited.

Edit using the “List Parameters” editing procedure
described on

page 488

.

2 Last Mem. Resume

This parameter displays whether the ICP1 will recall
the current scene when started up, or whether the
memory contents at the time the unit was turned off
will be recalled.

ON: The memory contents at the time the unit was
turned off will be recalled at startup.
OFF: The current scene will be recalled at startup.

The Last Men. Resume status can not be changed
from ICP1 controls.

3 Event Scheduler

Displays the current status of an event schedule setup
in the DME Designer will be executed or not.

ON: The event will be executed.
OFF: The event schedule will not be executed.
Edit using the “List Parameters” editing procedure
described on

page 488

.

NOTE

See

page 486

for details on how to use the Panel lock

feature.

NOTE

The User Defined Button are accessed as described in
the “Parameter Edit Display” section on

page 487

.

NOTE

See

page 490

for scene store procedure.

NOTE

This setting applies to individual devices only. Even if one
ICP1 unit is set to “Disable,” scene store operations will be
possible via another DME series in the same device group
that is set to “Enable.”

NOTE

The event schedule status can not be changed from the ICP1
controls.

1
2
3