beautypg.com

Auto gain control, Ol component added – Yamaha DME User Manual

Page 368

background image

Chapter 6 Component Guide

DME Designer Owner’s Manual

368

Auto Gain Control

The Auto Gain Control component automatically adjusts gain in response to input level, and is a
convenient way to maintain a constant output level with an input signal that varies in level. Mono and
stereo types are provided.

Double-click the component to open the component editor. The component editor is the same for
stereo and mono types, the only difference being the number of channels.

*1 The setting range of Response Time varies according to the operating frequency as follows:

44.1kHz: 447 msec to 2.14 sec, 48kHz: 411 msec to 1.96 sec, 88.2kHz: 224 msec to 1.07 sec, 96kHz: 206 msec to 984 msec

Name

Function

1

Input Meter

Displays the input signal level.

2

Output Meter

Displays the compensated output signal level.

Parameter

Setting Range

Function

3

Compensation Level

1 to 5

Sets the amount of gain compensation. Higher settings
produce more gain compensation. Caution: sudden
changes in this setting can result in output level
changes.

4

Response Time

*1

Sets the response time for gain compensation.
Effective for upward gain compensation (gain
increase), this parameter specifies the time it will take
for a gain increase of 6 dB. This parameter does not
affect gain reduction.

5

Noise Gate

ON/OFF

Turns the noise gate compensation on or off.

6

Bypass

ON/OFF

Turns gain compensation on or off.

1

2

3

5

4

6