Yamaha DME User Manual
Page 155

Chapter 3 Main Panel Window
DME Designer Owner’s Manual
155
5 Operation Security
Sets the functions that can be used by the user selected on the [User List] to the left. Selecting
a checkbox enables use of the corresponding function.
• [Edit]
You can change the following settings: editing in the Designer window, user control edit, user
defined parameter edit, word clock, scene edit, GPI and MIDI.
• [View DME Design Window]
Allows display of the Designer window.
• [Control Component Editor]
Allows parameter editing in the component editor.
• [View Component Editor]
Allows display of the component editor.
• [Change Configuration]
Allows switching between configurations.
• [Synchronization]
Allows synchronizing with the DME or SP2060 unit.
• [View Log Window]
Displays the “Event Logger” window.
• [Scene Store/Recall Level]
Sets the level at which scenes can be stored and recalled. Click the [
▲] and [▼] buttons or
enter a number into the box to set the level. While levels 1 through 10 are available, the range
of levels that can be actually set varies according to the level of the user doing the setting.
When a user is created, automatically this is set to “One level lower than the user above.” The
initially set level is the highest level that can be set for that user.
• [User Control Level]
Sets the user control level. Click the [
▲] and [▼] buttons or enter a number into the box to set
a level from 1 through 10. While levels 1 through 10 are available, the range of levels that can
be actually set varies according to the level of the user doing the setting.
When a user is created, automatically this is set to “One level lower than the user above.” The
initially set level is the highest level that can be set for that user.
[OK] Button
Applies any setting changes and closes the window.
[Cancel] Button
Closes the window without changing any settings.