Changes from V2.0 to V3.0
■ General
• DME8i-ES/DME8o-ES/DME4io-ES support.
• The DME Designer and DME-N Network Driver installers have been combined, so the
appropriate DME-N Network Driver version is now installed automatically with the DME Designer
application.
• The following connections to the Slave DME units are now possible when a DME Satellite unit is
assigned as the Device Group Master:
- USB/Ethernet connection to the computer (DME Designer).
- Cascade connection to control from the PM5D console (DME64N only).
■ Component
• Ambient Noise Compensator component added (
• Audio Detector component added (
• Auto Gain Control component added (
).
• Auto Mixer II component added (
).
• Simple Mixer component added (
).
• Room Combiner component added (
).
• Matrix Mixer and Router component variations added.
■ Main Panel Window
• To allow project information to be easily reproduced on a different computer, it is now possible to
export and import all necessary files at once, rather than only project files with the “.daf”
extension (
).
• A Device Information window that lists the status of all devices has been added (
).
• It is now possible to individually set each user control to determine whether it will open
automatically when the project file is opened (
).
• In accordance with the above change, the Startup User Control item has been removed from the
Security dialog box.
• It is now possible to assign Direct Parameter Value to the GPI input function, and assign Direct
Parameter Value and Audio Detector to the GPI output function (
,
• An option that automatically saves the project file (.daf extension) in the DME unit when going
online has been added (
• It is now possible to control internal DME-24N/DME8i-C/DME4io-C/DME8i-ES/DME4io-ES head
amps from a PM5D or other compatible mixing console (
).
• Remote control from AMX, Crestron, and similar controllers is now possible via Ethernet
connection only for DME Satellite units. (
• The display format of the parameter values displayed in the Remote Control Setup List and
Parameter List dialog box can now be switched between the internal settings and the values
displayed in the editor windows (
• The Event Logger window can now display additional error messages shown on the DME display
• It is now possible to set the DME unit so that the internally stored event log is not erased
(
• Improvements have been made to the additional error message information shown in the Event
Logger window.
• The DME unit internal clock and DME Designer time display now support daylight saving time
• Firmware updates can now be applied to entire device groups, for improved speed and
efficiency.