Right-click the block and select [Open MY-Card Editor] from the context menu to display the editor for it.

* Select “Disable” if you intend to make settings via the CobraNet network using the CobraNet Manager, for example. In such
cases selecting “Enable” may result in incorrect settings.

Section

Name/Parameter

Range

Function

1

Setting from this Window

Disable/Enable

When “Disable” is selected settings
made via the CobraNet network take
priority. When “Enable” is selected
settings made from the DME Designer
take priority.*

2

High Sampling
Mode

Input Format

Double Channel
Single

Selects the format for 88.2/96 kHz
sampling rates.
Linked to Output Format.

Double FS

ON/OFF

When turned ON the speed of the MY
card word clock output is doubled. Only
available when the card is set as the
word clock master.

Output Format

Double Channel
Single

Selects the format for 88.2/96 kHz
sampling rates.
Linked to Input Format.

3

Bundle
Number

Input

0 ~ 65279

Specifies the input bundle number.

Output

0 ~ 65279

Specifies the output bundle number.

4

Serial
Channel

Rx

OFF, 1 ~ 15

Specifies the serial receive channel.

Tx

OFF, 1 ~ 5

Specifies the serial transmit channel.

5

Properties

Bit Length

Bit Off
16bit
20bit
24bit

Specifies the output bit rate.
Output is muted when “Bit Off” is
selected.

6

Latency

5.33ms
2.67ms
1.33ms

Specifies the latency.

7

Advanced

-

Opens the “Advanced Settings”
Window. Refer to “Advanced Settings”
Window on

page 472

for details.

NOTE

Refer to the “MY16-CII Owner's Manual” or “CobraNet Manager Lite for YAMAHA Owner's Manual” for mote information on
CobraNet.

1

2

3

4

5

6