Filter type – Yamaha DME User Manual
Page 400
![background image](/manuals/231089/400/background.png)
Chapter 6 Component Guide
DME Designer Owner’s Manual
400
■ Filter Type
Various types of curves are available for changing the level. Click the [Type] button and select the
type from the menu.
• PEQ
This is a general parametric equalizer.
• L. SHELF (Low Shelving)
There is no sound attenuation at low frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the higher frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
• H.SHELF (High Shelving)
There is no sound attenuation at high frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the lower frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
• HPF
This is a high-pass filter (Q=0.7). Attenuates the low frequencies with a gentle curve (12 dB/
Oct).
• LPF
This is a low-pass filter (Q=0.7). Attenuates the high frequencies with a gentle curve (12 dB/
Oct).
Section
Parameter
Setting Range
Function
9
Equalizer
PEQ ON
ON/OFF
Turns the PEQ ON
)
Output
Level
-
∞ to ±0 dB
Sets the output signal level.
!
On
ON/OFF
Turns output ON.