8825/8830 Controller Setup Manual for Firmware 6.0

49

Configuring the System
Communication Defaults

Note: For more detailed information about connecting the Printer to a
network environment, refer to the
Network Administrator’s Guide.

Setting The SCSI Options

SCSI Purpose

These options are used to enable and configure the Controller SCSI port, if
available.

Software drivers may be required to be loaded at the customer workstation to
enable printing and control of the 8825/8830 Printer.

NOTE: When using SCSI port, the workstation device target number and the
printer device target number must be different.

When selecting the SCSI port, the following information is required:

ENABLING THE CONTROLLER SCSI PORT.

Range: ON or OFF

Default: ON

SETTING THE SCSI DEVICE TARGET NUMBER.

Range: 0 - 7

Default: 5

THIS OPTION SETS THE BUS TERMINATION AS REQUIRED.

Range: ON or OFF

Default: ON

Path to SCSI options

Display , press [ON-LINE], display , press [ENTER],
display , press [NEXT], display , press
[ENTER], display

Selecting SCSI options

Press ENTER to change any options. The first option is SCSI port enable
(ON or OFF). The default is ON. Press the ENTER key to change the mode.
Press the NEXT key to select either ON or OFF, when the desired mode is
displayed press the ENTER key.

Press the NEXT key to go to SCSI TARGET ID set option. Press the ENTER
key to change the target ID setting. Press the desired key (0 - 7) at the
Keypad. The displayed ID value will change, then press the ENTER key.

Press the NEXT key to go to SCSI BUS TERMINATION set mode. Press
ENTER to change the mode. Press the NEXT key to select either ON or
OFF, when the desired mode is displayed press the ENTER key.

Exiting SCSI options

Press EXIT to set up additional functions, or press the ON-LINE key to go
back to ON-LINE mode.