Chapter 5 Checking the installation prerequisites
89
BCM200/400 4.0 Installation and Maintenance Guide
Chapter 5
Checking the installation prerequisites
Refer to the following sections for information on BCM system installation prerequisites:
•
•
•
•
“Site telephony wiring requirements” on page 90
•
“System equipment, supplies, and tools” on page 91
General requirements
Before you install the BCM main unit or expansion unit, complete the following actions:
•
Determine the location for the BCM main unit (or expansion unit), telephones, and other
equipment based on spacing and electrical requirements.
•
Order the required trunks from the central office.
•
Ensure that you have all the equipment and supplies you need to install the system.
Environmental requirements
Ensure you meet the installation environmental requirements. The installation area must be:
•
a minimum of 4 m (13 ft.) from equipment such as photocopiers, electrical motors, and other
equipment that produces electromagnetic, radio frequency, and electrostatic interference
•
within 1.5 m (5 ft.) of a three-wire grounded electrical outlet
•
clean, free of traffic and excess dust, dry, and well ventilated
•
within the temperature ranges of 10°C and 40°C (50°F and 104°F)
•
between 20% and 80% non-condensing relative humidity
•
structurally strong enough and with enough space to support the BCM units
•
a minimum of 46 cm (18 in.) from the floor
Note: The installation area must be of sufficient height from the floor to prevent water
damage.