beautypg.com

Table 28 – Nortel Networks BCM200/400 User Manual

Page 120

background image

120

Chapter 8 Installing a media bay module (MBM)

N0060612

N0060612

Table 28

and

Table 29

show possible DS30 and offset configurations for each type of trunk MBM,

and the corresponding switch settings. For FEM settings, refer to

“FEM switch settings” on page

140

.

Table 28 Possible MBM DIP switch settings for 4x16, 8x16, DDIM, DTM, CTM, and GATM

DS30

bus #

Trunk MBM positioning

DIP switch settings

Offsets

4x16

Offsets

0,1, 2, 3

Line

Exten.

8x16

Offsets

0,1, 2

Line

Exten.

DDIM

Offset

0

CTM

Offsets

0, 1, 2, 3

CTM8

Offsets

0, 1, 2

GATM

Offsets

0, 1, 2, 3

GATM8

Offsets

0, 1, 2

1

2

3

(offset)

4

5

6

(DS30 #)

2

0

Picks

up

ch. #3

0

Picks

up

ch. #3

0

Picks

up

ch. #3

0

0

0

0

on on on on on on

0

1

1

1

1

1

1

on on off on on on

1

2

2

2

2

2

2

on off on on on on

2

3

3

3

on off off on on on

3

3

0

Picks

up

ch. #4

0

Picks

up

ch. #4

0

Picks

up

ch. #4

0

0

0

0

on on on on on off

0

1

1

1

1

1

1

on on off on on off

1

2

2

2

2

2

2

on off on on on off

2

3

3

3

on off off on on off

3

4

0

Picks

up

ch. #5

0

Picks

up

ch. #5

0

Picks

up

ch. #5

0

0

0

0

on on on on off on

0

1

1

1

1

1

1

on on off on off on

1

2

2

2

2

2

2

on off on on off on

2

3

3

3

on off off on off on

3

5

0

Picks

up

ch. #6

0

Picks

up

ch. #6

0

Picks

up

ch. #6

0

0

0

0

on on on on off off

0

1

1

1

1

1

1

on on off on off off

1

2

2

2

2

2

2

on off on on off off

2

3

3

3

on off off on off off

3

6

0

Picks

up

ch. #7

0

Picks

up

ch. #7

0

Picks

up

ch. #7

0

0

0

0

on on on off on on

0

1

1

1

1

1

1

on on off off on on

1

2

2

2

2

2

2

on off on off on on

2

3

3

3

on off off off on on

3

7***

Not

supported

Not

supported

Not

supported

0

0

0

0

on on on off on off

0

1

1

1

1

on on off off on off

1

2

2

2

2

on off on off on off

2

3

3

on off off off on off

3

MBM set to offset 0

MBM set to offset 1

MBM set to offset 2

MBM set to offset 3

Each shaded square represents the amount of the DS30 bus, and the offset, which the MBM requires.
***If your system is configured with a 3/5 DS30 bus split, DS30 bus 7 is not available to MBM and DS30 bus 6 is not

supported for the 4x16 and DDIM.
***The offset for DTM is always zero (0).