Chapter 9 Connecting the cables

151

BCM200/400 4.0 Installation and Maintenance Guide

Figure 78

shows the wiring pin-out for a BRIM S/T to the service provider. This diagram also

applies to an S-Loop BRI and is capable of having S-Loop devices connected to it (video
phones, terminal adapters, group 3 fax machines). The T setting on the BRI Loop is used when
connected to the CO or PSTN.

Figure 78 BRIM S/T RJ-45 wiring array

3

Insert the connector into the jack on the MBM.

Refer to the BCM 4.0 Administration Guide for steps about changing the default settings for
each line or loop.

4

You can now use Element Manager to configure the lines or sets associated with the MBM
(see the BCM 4.0 Administration Guide).

To connect the GATM, G4x16, or G8x16

1

On the front of the MBM, locate the amphenol connector.

2

Wire one end of the cable to the demarcation blocks of the building.

Warning: The BRIM S/T must only be connected to an NT1 provided by the service
provider. The NT1 must provide a Telecommunication Network Voltage (TNV) to Safety
Extra Low Voltage (SELV) barrier.

Note: For G4x16 and G8x16, the lower 25-pair connector is the analog trunk part of the
module and is wired the same as the GATM.

8 7 6 5 4 3 2 1

1 2 3 4 5 6 7 8

BRIM S/T connector

RJ-45 jacks

Pin #/connection

System side

1 not used
2 not used
3 +Rx
4 +Tx
5 -Tx
6 -Rx
7 not used
8 not used

+Tx
+Rx
-Rx
-Tx