Table 52 – Nortel Networks BCM200/400 User Manual
Page 155
Chapter 9 Connecting the cables
155
BCM200/400 4.0 Installation and Maintenance Guide
2
Install the telephones and peripheral equipment (if it is a new system):
a
Attach the cables for the telephones to the connecting blocks.
b
Install the telephones. Refer to
“Installing telephones and peripherals” on page 169
.
3
Plug the female amphenol connector into the interface on the front of the MBM.
4
Set up any mobile system you are using.
•
Ensure the base stations are correctly installed and connected to the appropriate MBMs on
the BCM system. In the case of the Wireless LAN IP telephone system, ensure that the
access point is correctly set up to connect to the BCM system LAN or WAN.
•
Configure and register the handsets according to the instructions provided for each type of
system.
Table 52 ASM wiring chart
Pin
Wire color
Port
Set #
Wiring for an ASM 8 or GASM8
26
White-Blue
X01
1
1
Blue-White
X01
1
27
White-Orange
X02
2
2
Orange-White
X02
2
28
White-Green
X03
3
3
Green-White
X03
3
29
White-Brown
X04
4
4
Brown-White
X04
4
30
White-Slate
X05
5
5
Slate-White
X05
5
31
Red-Blue
X06
6
6
Blue-Red
X06
6
32
Red-Orange
X07
7
7
Orange-Red
X07
7
33
Red-Green
X08
8
8
Green-Red
X08
8
34-50
no connection
9-25
Note: Refer to
“Assigning line and extension numbers” on page 124
between the DS30 channel number and the DNs. Configuration information is included in
the BCM 4.0 Administration Guide.
8T
33R
32R
7T
31R
6T
30R
5T
29R
4T
28R
3T
27R
2T
26R
1T
25-pair female
amphenol
connector
WARNING:
Ensure that you have Tip (T) and Ring (R)
connected to the appropriate pins.