beautypg.com

Wiring the fem, To connect the fiber cables – Nortel Networks BCM200/400 User Manual

Page 156

background image

156

Chapter 9 Connecting the cables

N0060612

N0060612

Wiring the FEM

A fiber expansion module (FEM) allows you to upgrade from a Norstar system to a BCM system
by reusing the Norstar MBMs. The MBMs connect to the FEM using the same fiber cable that
connected them to the Norstar fiber expansion card.

To connect the fiber cables

1

Ensure the BCM system is powered up and functional.

2

Connect the fiber cables from the Norstar MBMs to the jacks on the FEM.

a

Connect the Norstar Line Modules to the FEM beginning at fiber port 1.

b

Connect Norstar Extension Modules to the FEM beginning at fiber port 6.

3

Change the DN records in Element Manager or change the set wiring, as required, to match
your system.

Warning: Handling optical fiber cables

If the cable is too long, ensure that it is coiled correctly using the fiber spool. Coil excess
fiber cable carefully around the spool provided. Do not bend the cable around any tight
corners. Bends in the fiber cable must not be less than 100 mm in diameter. Place the fiber
cable spool into a slot at the back of the cable trough in the Norstar MBM.

Note: The DIP switch settings you chose determine which FEM ports are available. If you
enable all six FEM ports, the BCM system has no more DS30 resources available.
Therefore, you cannot connect more MBMs to the system.

Warning: When you connect a Norstar station MBM to an FEM, the extension numbers
of the telephones connected to the station MBM may change. To keep the same extension
numbers, you must change the DNs of the telephones or change the telephone wiring to
correspond with the required DNs.

Note: If you connect a Norstar station MBM amphenol cable directly to a DSM, you do
not have to modify the wiring connections. Ensure you select the correct DS30 number.