Bcm system does not function, Emergency telephone does not function, Ata2 does not function – Nortel Networks BCM200/400 User Manual
Page 235
Chapter 19 System monitoring and troubleshooting
235
BCM200/400 4.0 Installation and Maintenance Guide
BCM system does not function
The BCM system can experience a complete failure for any of the following reasons:
•
Power supply failure
•
Incorrect power supply connections
•
AC power failure
Emergency telephone does not function
If the emergency telephone is connected to the system, refer to
“To troubleshoot the emergency
telephone on the system” on page 235
.
If the emergency telephone is connected to the CTM, refer to
“To troubleshoot the emergency
telephone connected to a CTM” on page 235
.
To troubleshoot the emergency telephone on the system
1
Check the Power LED on the ASM8 to check that the ASM8 is receiving power.
2
Check that the emergency telephone has dial tone.
3
Check the external line and emergency telephone connections.
4
To avoid damage to the emergency telephone, connect the telephone directly to the external
line and check for dial tone.
5
Replace the MSC.
To troubleshoot the emergency telephone connected to a CTM
1
Check that the system has a CTM installed.
2
Check that there is no dial tone at the emergency telephone.
3
Replace the CTM.
ATA2 does not function
If the BCM ATA2 does not function, use these procedures to troubleshoot the problem.
To troubleshoot the ATA2
1
Make sure there is AC power connected to the ATA2 unit.
2
Make sure that the ATA2 is in the tones off mode (for data applications only).
3
Correctly configure the ATA2 telephone port for data communication.
4
Allow sufficient start-up time.