beautypg.com

Removing a bcm400 standard power supply, To remove a bcm400 standard power supply – Nortel Networks BCM200/400 User Manual

Page 290

background image

290

Chapter 23 Replacing or upgrading a power supply

N0060612

N0060612

10 Loop the cables together and tie-wrap to the side of the power supply to remove P1, P9, P3,

P7/8 excess cable length. Fold the cables to the rear of the main unit and secure with a
tie-wrap. Ensure the cables are tied far enough back so they do not interfere with the insertion
of the base function tray.

11 Attach the fan plug to the I/O card Fan #1 connection. Loop excess fan cable length under the

I/O card.

12 Insert the base function tray fully into the main unit. Ensure the base function tray does not

interfere with any cabling.

13 Replace the main unit top cover. See

“Installing the main unit top cover” on page 254

.

14 Press the power supply switch to the ON position (if applicable). Plug the BCM power cord

into an AC power outlet.

15 Restore the BCM system to operation. For details, refer to

“Restarting the system after

maintenance” on page 240

. The BCM system starts when you connect the AC power cord.

Wait for the start-up process to finish.

16 Monitor the Power LED on the base function tray. Refer to

Table 18 on page 79

.

a

If the BCM system does not power up, press the reset button on the base function tray
front panel.

b

If the Power LED is red, then the system generated an alarm. See

“Resolving alarm

conditions” on page 225

.

c

If the Power LED is green, the system is operating normally.

Removing a BCM400 standard power supply

Use this procedure to remove the standard power supply from a BCM400 main unit.

To remove a BCM400 standard power supply

1

Set up the BCM400 for maintenance (see

“Performing a system shutdown” on page 239

).

2

Disconnect all cables from the front of the base function tray.

Note: Verify the power supply cables are connected correctly and do not interfere with
any internal components.

Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.

Warning: Power supply cable management is critical. Loose or incorrectly positioned
cables can result in cable damage.