Null modem cable setup, To display the configuration menus – Nortel Networks BCM200/400 User Manual

Page 188

background image

188

Chapter 13 Initializing the system

N0060612

N0060612

Null modem cable setup

Table 66

and

Figure 92

show the correct wiring for the BCM serial port of the null modem cable.

Figure 92 Serial pinout

Transmission parameters:

9600 bits per second

8 data bits

no parity

1 stop bit

hardware flow control

To display the configuration menus

1

Attach the null modem cable to the serial port on the BCM main unit.

2

Attach the other end of the null modem cable to the serial port on the terminal or computer.

3

Ensure that the BCM main unit and your terminal or computer are turned on.

4

Access the BCM main unit using one of the following methods:

Table 66 Serial port pinout

Pin

Signal

Pin

Signal

1

Data Carrier Detect (DCD)

6

Data Set Ready (DSR)

2

* Serial data in (RX)

7

Request to Send (RTS)

3

* Serial data out (TX)

8

Clear to Send (CTS)

4

Data Terminal Ready (DTR)

9

Ring Indicator (RI)

5

* Ground

* required connections

Note: For instructions about how to set the transmission parameters, refer to the terminal
or terminal emulation program documentation. The BCM system supports carriage return.

Note: The location of the transmit (TX) and receive (RX) pins on your terminal can vary.
Refer to your terminal or computer documentation to confirm pin locations.