beautypg.com

Asm 8 and gasm8 switch settings – Nortel Networks BCM200/400 User Manual

Page 135

background image

Chapter 8 Installing a media bay module (MBM)

135

BCM200/400 4.0 Installation and Maintenance Guide

ASM 8 and GASM8 switch settings

In a single-density configuration, such as for DS30 6 or 7 when they are set to the default PDD,
only offset 1 and 2 are available to ASM 8/GASM8. In a double-density configuration, you can
install four GASM8s for each DS30 bus.

Table 42

shows the switch settings for each DS30

number and the dialing numbers (DNs) assigned to each DS30 number.

Table 42 ASM 8 settings

Select

bus

Select

offset

Enter these switch

settings

To

assign

these

DNs

Select

offset

Enter these switch

settings

To

assign

these

DNs

**Custom
DN range

1

2

3

4

5

6

1

2

3

4

5

6

2.5 system upgraded to 3.0

3.0 and newer systems

2

0

on on on on on on 221-228

0

on on on on on on 221-228

1

on on off on on on 229-236

1

on on off on on on 229-236

2

on off on on on on 377-384

2

on off on on on on 237-244

3

on off off on on on 385-392

3

on off off on on on 245-252

3

0

on on on on on off 237-244

0

on on on on on off 253-260

1

on on off on on off 245-252

1

on on off on on off 261-268

2

on off on on on off 393-400

2

on off on on on off 269-276

3

on off off on on off 401-408

3

on off off on on off 277-284

4

0

on on on on off on 253-260

0

on on on on off on 285-292

1

on on off on off on 261-268

1

on on off on off on 293-300

2

on off on on off on 409-416

2

on off on on off on 301-308

3

on off off on off on 417-424

3

on off off on off on 309-316

5

0

on on on on off off 269-276

0

on on on on off off 317-324

1

on on off on off off 277-284

1

on on off on off off 325-332

2

on off on on off off 425-432

2

on off on on off off 333-340

3

on off off on off off 433-440

3

on off off on off off 341-348

6

0

on on on off on on 285-292

0

on on on off on on 349-356

1

on on off off on on 293-300

1

on on off off on on 357-364

2

on off on off on on 441-448

2

on off on off on on 365-372

3

on off off off on on 449-456

3

on off off off on on 373-380

7***

0

on on on off on off 301-308

0

on on on off on off 381-388

1

on on off off on off 309-316

1

on on off off on off 389-396

*****2

on off on off on off 457-464

*****2

on off on off on off 397-404

*****3

on off off off on off 465-472

*****3

on off off off on off 405-412

** The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a

different Start DN, enter the range in the blank column.
*** If your system is configured with a 3/5 split, DS30 7 is not available.
*****Available only on systems set to double density with a 2/6 DS30 split.