Table 25, Reco – Nortel Networks BCM200/400 User Manual
Page 109
Chapter 8 Installing a media bay module (MBM)
109
BCM200/400 4.0 Installation and Maintenance Guide
2
Use the number of lines and the number of lines per MBM to determine how many MBMs you
need.
For example:
•
If you require 24 T1 digital lines, you need 1 DTM because a single DTM can handle 24
T1 lines (North America).
•
If you require 2 analog lines and 24 T1 digital lines, you need 1 GATM4 and 1 DTM.
Table 25 Determine trunk MBM requirements
Type of lines
Number
of lines
Type of MBM
Number of lines
per MBM
Number of MBMs
required
T1 digital lines
DTM
24
______ DTM
Universal T1 MUX digital
lines
DDIM
24
(also requires a full
DS30 bus for the data
module)
______ DDIM
PRI digital lines (NA)
DTM
23
______ DTM
E1 digital lines
DTM
30
______ DTM
PRI digital lines (EMEA)
DTM
30
______ DTM
Analog lines
CTM4
4
______ CTM
Analog lines
CTM8
8
______ CTM
Analog lines
GATM4
4
______ GATM
Analog lines
GATM8
8
______ GATM
Analog lines
4x16 combination MBM
4
(also requires all of
the next DS30 bus for
the DSM16 part)
______ 4x16
Analog lines
8x16 combination MBM
8
(also requires all of
the next DS30 bus for
the DSM16 part)
______ 8x16
BRI ISDN lines
BRIM S/T
4 ISDN loops
______ BRIM S/T
Note: Although the DTM supports several types of digital lines, you cannot connect
different types of lines to the same DTM. You can add a maximum of three DTMs or
DDIMs to your BCM system.
Tip: The BCM400 main unit holds a maximum of four MBMs. If you require more