Chapter 8 Installing a media bay module (MBM)

109

BCM200/400 4.0 Installation and Maintenance Guide

2

Use the number of lines and the number of lines per MBM to determine how many MBMs you
need.

For example:

If you require 24 T1 digital lines, you need 1 DTM because a single DTM can handle 24
T1 lines (North America).

If you require 2 analog lines and 24 T1 digital lines, you need 1 GATM4 and 1 DTM.

Table 25 Determine trunk MBM requirements

Type of lines

Number
of lines

Type of MBM

Number of lines
per MBM

Number of MBMs
required

T1 digital lines

DTM

24

______ DTM

Universal T1 MUX digital
lines

DDIM

24
(also requires a full
DS30 bus for the data
module)

______ DDIM

PRI digital lines (NA)

DTM

23

______ DTM

E1 digital lines

DTM

30

______ DTM

PRI digital lines (EMEA)

DTM

30

______ DTM

Analog lines

CTM4

4

______ CTM

Analog lines

CTM8

8

______ CTM

Analog lines

GATM4

4

______ GATM

Analog lines

GATM8

8

______ GATM

Analog lines

4x16 combination MBM

4
(also requires all of
the next DS30 bus for
the DSM16 part)

______ 4x16

Analog lines

8x16 combination MBM

8
(also requires all of
the next DS30 bus for
the DSM16 part)

______ 8x16

BRI ISDN lines

BRIM S/T

4 ISDN loops

______ BRIM S/T

Note: Although the DTM supports several types of digital lines, you cannot connect
different types of lines to the same DTM. You can add a maximum of three DTMs or
DDIMs to your BCM system.

Tip: The BCM400 main unit holds a maximum of four MBMs. If you require more
MBMs, the BCM expansion unit supports a maximum of six additional MBMs.