Installing a hard disk into, Installing a hard disk into a standard – Nortel Networks BCM200/400 User Manual
Page 276
276
Chapter 22 Replacing the hard disk
N0060612
N0060612
To remove a mirror hard disk from a RAID hard disk cage
1
Remove the RAID hard disk cage from the main unit (or advanced function tray) (see
“Removing a hard disk cage” on page 266
2
Disconnect the hard disk IDE connectors from the mirror hard disk and RAID card.
3
Unscrew the hard disk retainer screws from both sides of the RAID hard disk cage (see
). Lift the mirror hard disk IDE ribbon cable to access the retainer screw. Place the retainer
screws in a safe location.
4
Remove the mirror hard disk from the RAID hard disk cage (see
Figure 130 Remove the mirror hard disk from the RAID hard disk cage
5
Place the hard disk on a flat, clean, and static-free surface.
Installing a hard disk into a standard configuration hard disk cage
Use this procedure to install a single hard disk into a hard disk cage for a standard BCM200 or
BCM400 system.
Caution: Use only Nortel-approved replacement components. Contact your account
representative for the current list of approved replacement parts.
Caution: It is vital that you connect the correct IDE ribbon cables to the correct hard
disks. Connect the primary IDE ribbon cable to the primary hard disk. Connect the mirror
IDE ribbon cable to the mirror hard disk.
Disconnect the mirror hard disk retainer screws
Slide the mirror hard disk out from
the hard disk cage
3
Disconnect the mirror hard disk IDE ribbon cable
from the hard disk and RAID card
1
2
BCM400 RAID shown
to access the hard disk