Brim wiring chart, Appendix c brim wiring chart, Appendix c – Nortel Networks BCM200/400 User Manual
Page 351
Appendix C BRIM wiring chart
349
BCM200/400 4.0 Installation and Maintenance Guide
Appendix C
BRIM wiring chart
The digital BRI ISDN lines are connected to the BRIM through the RJ-45 jacks on the front of the
media bay module (MBM) (see
). You can connect up to four BRI ISDN lines to the
BRIM.
, and
apply to S-Loop and T-Loop connections. S-Loop connections are used
to connect S-Loop devices, such as video phones, terminal adapters, and group 3 fax machines.
The T-Loop connections are used to connect to the CO/PSTN.
Figure 192 BRIM RJ-45 ports
lists the wiring details for the RJ-45 ports.
Warning: For a U-Loop connection, the BRIM must be connected only to an NT1
provided by the service provider. The NT1 must provide a Telecommunication Network
Voltage (TNV) to Safety Extra Low Voltage (SELV) barrier.
Table 90 BRIM RJ-45 port wiring
Pin
Signal
Signal on system side
1
No connection
No connection
2
No connection
No connection
3
+ Receive (+Rx)
+Tx
4
+ Transmit (+Tx)
+Rx
5
- Transmit (-Tx)
-Rx
6
- Receive (-Rx)
-Tx
7
No connection
No connection
8
No connection
No connection
1 2 3 4 5 6 7 8
RJ-45 pin-out
RJ-45 jacks
BRIM